background image

 

 

 

 

________________________________________________________________________________________________________________________________________________________________________________________________________________________  

10 

 

Product Manual  Type:

 NEB/3U

 

07-01-02-02-E-V0605.DOC

 

6 Miscellaneous 

Guarantee: 

Only when using original SSD Drives component racks, drives and ballast resistors SSD Drives guarantees 
for 1 years . 
 

Plug in and out the module: 

The module may only be plugged in i.e. out when there is no voltage. 
 

 

    

Attention:

 

 
 
The power-supply plug-in module may only be plugged out 30 
seconds after the green LED "Ucc ok", mounted on the front, is 
out. (Discharge time of the capacitor) 
 

 

ISO 9001: 

The devices are produced in accordance with DIN ISO 9001. 
All devices are subject to a 100% final test. 
 

VDE-guidelines: 

The device meets the requirements of the VDE 0100 and VDE 0160. 
 

EG-certificate of conformity given for: 

EN 50 081-2 

 interference emission high frequency emission 

pr EN 50 082-2  immunity to interference against HF and impulses 
vfg 242/1991 

 "barrage" jammer 

 
The low-voltage guidelines are not met yet. 
 

further information see: 

 

EG-certificate of conformity 16.7.1.2 and 

 

Enclosure I.1 to the EG-certificate of conformity 16.7.1.2 

Summary of Contents for NEB/3U

Page 1: ...07 01 02 02 E V0605 DOC NEB 3U Power supply plug in module Product Manual ...

Page 2: ...ons that relate to this document UL 07 01 05 06 635 Product Manual UL 07 01 01 01 Rack 3U Product Manual SSD Drives GmbH All rights reserved No portion of this description may be produced or processed in any form without the consent of the company Changes are subject to change without notice SSD Drives has registered in part trademark protection and legal protection of designs The handing over of ...

Page 3: ...B 3U 3 CONTENTS page The most important thing first 4 1 Description 5 2 Type code 6 2 1 Typical Example 6 3 Front view Power supply plug in module 7 4 Technical data 8 5 Assignment Power connectors 9 6 Miscellaneous 10 7 Adjustments 11 7 1 The ballast power is adjusted in production 11 8 Fuses Monitorings 11 8 1 Fuse for overload protection 11 8 2 Fuse for conducting path protection 11 8 3 Switchi...

Page 4: ...n of the product in combination with dangerous voltage can lead to injuries In addition damage can also occur to motors or other products Therefore please observe our safety precautions strictly Safety precautions We assume that as an expert you are familiar with the relevant safety regulations especially in accordance with VDE 0100 VDE 0113 VDE 0160 EN 50178 the accident prevention regulations of...

Page 5: ...or 3 230 V AC The device makes from the power supply voltage the rated voltage of 325 V DC for the intermediate circuit for the servo drive 635 from SSD Drives The power supply module is located extremely left in the rack The module can only be delivered with ballast circuit The ballast input power integrated in the power supply module is ventilated according to the adjustment 30 W 55 W The power ...

Page 6: ...0 30 W internal at 10 A continuous current uncooled 055 55 W internal at 15 A continuous current cooled 100 100 W external at 25 A continuous current uncooled or cooled e Heights units 3 3 U appr 128 4mm f Code adjusted ballast input power A1 Details see chapter 7 A2 B2 C1 g Special b Protection against condensation c Additional capacitors total capacity 900 µF standard 450 µF h b c The external b...

Page 7: ..._______________________________________________________________________________________ 07 01 02 02 E V0605 DOC Product Manual Type NEB 3U 7 3 Front view Power supply plug in module Dimensions Width approx 40 0 mm 8 HP Hight approx 128 4 mm 3 U Depth approx 160 0 mm plus jutting out H15 strip Arrangement standard left rack socket ...

Page 8: ...055 3 B2 8 15 55 x 54 NEB 25 100 3 A2 8 25 25 100 x 33 NEB 25 100 3 C1 8 25 25 100 x 22 Specifications concerning supply voltage 230 V AC Fan L220 K Air flow rate 80 m h Supply voltage 230 V 50 Hz General data minimum nominal maximum dimension Power connector 230 255 Veff Mains frequency 45 50 60 Hz Feed in 3 phase or 1 phase Output voltage 325 360 V DC Ucc Ballast res On 370 376 380 V DC Ub Balla...

Page 9: ...____ 07 01 02 02 E V0605 DOC Product Manual Type NEB 3U 9 5 Assignment Power connectors View from the rear of the rack Clamps Function descriptin 4 Ucc 6 Ucc 8 Ucc DC bus voltage 10 L1 12 L1 14 L2 16 L2 18 L3 20 L3 Supply voltage 1 or 3 230 V AC 22 Ucc 24 Ucc 26 Ucc DC bus voltage 28 RB 30 RB External Ballast resistor 32 GND Ground Attention With 1 phase connection clamps 14 and 16 are used as zer...

Page 10: ...Attention The power supply plug in module may only be plugged out 30 seconds after the green LED Ucc ok mounted on the front is out Discharge time of the capacitor ISO 9001 The devices are produced in accordance with DIN ISO 9001 All devices are subject to a 100 final test VDE guidelines The device meets the requirements of the VDE 0100 and VDE 0160 EG certificate of conformity given for EN 50 081...

Page 11: ...pen 220 closed 220 100 33 external B 2 standard closed 220 closed 220 55 54 internal x C 1 special open 470 220 open 470 100 22 external C 2 special open 470 160 closed 120 200 22 external 8 Fuses Monitorings 8 1 Fuse for overload protection F100 intermediate circuit overload 30A slow acting 8 2 Fuse for conducting path protection FB1 ballast circuit conducting path protection 10 A slow acting 8 3...

Page 12: ...______________________________________________________________________________________________ 12 Product Manual Type NEB 3U 07 01 02 02 E V0605 DOC 9 Update list Version Amendment Chapter Date Name Remarks V05 16EHST96 None 11 03 99 K Stadler ET design V0605 separate German all Logos English SSD Drives 18 02 05 N Dreilich ...

Page 13: ...5 108407 SWITZERLAND Indur Antriebstechnik AG Margarethenstraße 87 CH 4008 Basel Fax Tel 41 61 27929 00 41 61 27929 10 U S A SSD Drives Inc 9225 Forsyth Park Drive Charlotte North Carolina 28273 3884 Fax Tel 1 704 588 3246 1 704 588 3249 CHINA Eurotherm Pty Ltd Apt 1805 8 Building Hua Wei Li Chao Yang District Beijing 100021 Fax Tel 86 10 87785520 86 10 87790272 GERMANY SSD DRIVES GmbH Von Humbold...

Reviews: