4 Device overview
Power supply, line rectifiers
Controller
NG 602-...
Bus line rectifier in a 6-grid housing.
Primary: 230 V AC, 50/60 Hz
Secondary: 12 V AC, 1.6 A and
23.3 V DC - 0.3 A stabilized.
Supply to the 1+n system, door
release and lighting for the call
button modules.
GC 612-...
Group controller in 6-grid housing
for internal speech operation.
Connection of max. 6 in-housetele-
phones HTC 811-… Calls can be
made between the connected in-
house telephones.
8 DIL switch for programming.
Supply 24 V DC, max. 300 mA
Max. contact load for secondary
signal unit 24 V, 2 A AC/DC
TR 603-...
Transformer in a 3-grid housing.
Primary: 230 V AC, 50/60 Hz
Secondary: 12 V AC, 1.3 A
Additional supply for lighting the
name signs or door releases.