25
AS-Ta-64/1 Siedle Vario with
DoorCom Analog DCA 612-…
Functional
Calling and speech between the
door station and connected in-house
telephones HTS/HTC 811-…
An existing call cannot be listened in
to from other in-house telephones.
Door release button for the door
release function, light button for the
light switching function. Illuminated
light button at the door station with
potential-free switching contact.
Connection of a storey call button
(ERT) for calling from an apartment
door.
Different ring tones for calls from
the front door, apartment door and
for internal calls.
Up to 3 call buttons can be con
-
nected at the DoorCom DCA 612-…
and can call different users of a
telephone system. Users are dialled
using the dual tone multifrequency
dialling method DTMF.
Call tones with HTS 811-…
A call from the door produces a
3-tone call, from the storey door a
2-tone call.
Call tones with HTC 811-…
On a door call, a 3-tone chime
sounds, without connection of ter-
minal G a 3-tone call. On a storey
call, a 2-tone call sounds.
Connection of additional in-house
telephones or door stations is pos-
sible without switchover device. To
ensure tamper-proof connection of
the door release, the door release
controller CTÖ 602-… has to be
used. Additional cores are required
for this.
Supplementary functions
• Internal speech communication
between the in-house telephones
HTC 811-… and group controller
GC 612-… is possible.
• Switching and control functions
are possible with the switching/
remote controller SFC 602-…
• A secondary signal unit NS 711-…
is possible in parallel with an in-
house telephone HTS/HTC 811-…
• A parallel door call to a maximum
of 2 HTS/HTC 811-… units or
NSC 602-…/NS 711-… is possible
simultaneously. Using the group
controller GC 612-… a parallel call
is possible to up to 6 in-house tel
-
ephones.
Remarks
a)
Line rectifier NG 602-… can
supply 1 door release and a
maximum of 50 call button modules
with LED lighting TM 612-1,
-2, -3, and -4. With more than
50 illuminated call button modules,
an additional TR 603-… is required.
• 12 V AC consumers in the AS plan:
Door release appr. 600 mA
LED lighting per call button module
20 mA
• Door release contact load in the
door loudspeaker max. 24 V AC, 2 A
• Light contact load in the door
loudspeaker max. 24 V AC, 2 A
b)
Door release 12 V AC, use at least
20 Ohm (e.g. TÖ 615-…)
c)
Conductor length from the
in-house telephone to the storey
call button ERT max. 50 m/164 ft.
The light button in the in-house
telephone switches the contact in
the door loudspeaker from c to Li for
0.8 seconds, load max. 24 V, 2 A.
d)
The maximum distance of the
DCA 612-… to the NG 602-… is
20 m. For greater distances, an
additional transformer is required
for the DCA 612-… If several
DCA 612-… units are used within
a system, each DCA 612-… must
be supplied by its own transformer
(TR 603-…).
• At call button module TM 612-…
there must not be a connection
from the “b” terminal to another
terminal of the door station, except
if several TM 612-… units are used
in a system. Only then may the “b”
terminals be connected to each
other.
Summary of Contents for AS-Ta-64/1
Page 1: ...System Manual 1 n technology Issue 2013 ...
Page 7: ...7 ...
Page 16: ...16 5 Installation AS Ta 64 1 Siedle Vario Remarks Appliance requirement ...
Page 20: ...20 5 Installation AS Ta 64 1 Siedle Classic Remarks Buttons Appliance requirement ...
Page 22: ...22 5 Installation AS Ta 64 1 Siedle Steel Remarks Buttons Appliance requirement ...
Page 26: ...26 5 Installation AS Ta 64 2 Siedle Vario with 2 door stations Remarks Appliance requirement ...
Page 30: ...30 5 Installation AS Ta 64 3 Siedle Vario with 3 door stations Remarks Appliance requirement ...
Page 53: ...53 ...