40
6 Supplementary functions
Group controller GC 612-…
The group controller GC 612-… in
the 6-grid housing is used for the
connection of a group of max. 6
in-house telephones HTC 811-…
In-house telephones connected to
the group controller the buttons 1–6
can be used to call and communi-
cate with other in-house telephones.
The door station is switched off
during an internal call.
With the GC 612-… it is also pos
-
sible to signal a door call to more
than 2 in-house telephones. For this
function HTS 811-… units can also
be used.
Several group controllers can be
used in an intercom unit. In addition,
switching and control functions can
be executed from every connected
in-house telephone HTC 811-… If
a door call is made to an in-house
telephone which is currently con-
ducting a call, this is interrupted and
an engaged signal sounds. After
replacing the receiver the door call
is signalled.
Call differentiation HTC 811-…
Main door call: 3-tone chime,
storey door call: 1st and 2nd chime
tone of the three-tone chime, sub-
sequently normal 3-tone chime
Internal call: 3-tone call
Storey call: 2-tone call (ERT button
connected directly at the HTC)
Door parallel call
The door call can be signalled simul-
taneously in conventional systems
at up to 2 in-house telephones.
With the GC 612-… it is possible to
signal a door call at up to 6 in-house
telephones. This always actuates
two in-house telephones simultane-
ously. With more than two parallel
telephones, these are always called
in pairs with a time offset.
Speech connection
For each group controller, only one
call can be held. If an internal call
already exists within a group, it is
possible to place an additional call
from the door loudspeaker only to
another in-house telephone which
is not directly connected to the
GC 612-… The group controller acts
in relation to the 1+n side circuit
installation in the same way as an
in-house telephone. Each GC 612-…
requires the NG 602-… for its own
power supply.
Switching and control functions
• Switching and control functions
are possible in conjunction with the
SFC 602-… A maximum of 6 control
functions can be actuated from each
HTC 811-… in the group. Control
functions can be executed at any
time with the receiver down or
during an existing speech connec-
tion. Settings at DIL switch 2 may be
necessary in the in-house telephones
HTC 811-…
Operating elements GC 612-…:
• One programming switch in order
to enable the programming mode
• One status LED to display the pro-
gramming mode and saving.
• 8 DIL switches to determine the
required functions/for programming.
• DIL switches 1–6 for assignment
of the door call to the in-house tel-
ephones 1 to 6
• DIL switch 7
ON
SFC 602-… is connected
at the group controller
OFF
SFC 602-… is connected
at the door loudspeaker
If DIL switch 7 is set to OFF, DIL
switch 8 is non functional.
• DIL switch 8
ON
Control functions 5 and 6
act on the SFC 602-… at
the door loudspeaker
OFF
Control functions 5 and 6
act on the SFC 602-… at
the group controller
Internal call
From each HTC 811-… unit in
the group, each other in-house
telephone of
the same
group can
be called. The following procedure
has to be observed here: Pick up the
receiver and only then actuate the
required call button at the in-house
telephone.
Secondary signal unit
For door call 1 (terminal 7.1) a
potential-free contact S1/S2 is
available at the GC 612-…
(max. 24 V, 2 A).
Installation
The in-house telephones at the
GC 612-… are installed in star for
-
mation.
Maximum conductor lengths
between:
• GC 612-… and telephones
100 m/328 ft.
• GC 612-… and door station
500 m/1640 ft.
Wiring diagram without video
AS-Ta-74/1 on page 32
As-delivered status of the
GC 612-…
The door call inputs are assigned
to telephones 1:1. Terminal 7.1
(input 1) is assigned to the 1st tele-
phone, terminal 7.6 (input 6) to the
6th telephone.
Summary of Contents for AS-Ta-64/1
Page 1: ...System Manual 1 n technology Issue 2013 ...
Page 7: ...7 ...
Page 16: ...16 5 Installation AS Ta 64 1 Siedle Vario Remarks Appliance requirement ...
Page 20: ...20 5 Installation AS Ta 64 1 Siedle Classic Remarks Buttons Appliance requirement ...
Page 22: ...22 5 Installation AS Ta 64 1 Siedle Steel Remarks Buttons Appliance requirement ...
Page 26: ...26 5 Installation AS Ta 64 2 Siedle Vario with 2 door stations Remarks Appliance requirement ...
Page 30: ...30 5 Installation AS Ta 64 3 Siedle Vario with 3 door stations Remarks Appliance requirement ...
Page 53: ...53 ...