6 Supplementary functions
Storey controller ETC 602-…
The storey controller in the 6-grid
housing is used to connect a storey
door station. Up to a maximum of
7 storey door stations can be con
-
nected to a storey controller. In
addition to a call with the main door
station in the side circuit, a call is
also possible from a storey door sta-
tion to an in-house telephone. If a
call exists from a storey door station,
it is not possible to place a call to
any of the other in-house telephones
connected to the ETC 602-… If you
wish as many simultaneous calls to
be possible as there are storey door
loudspeakers, for each storey door
loudspeaker 1 ETC 602-… with an
NG 602-… is required.
In addition, a call can be held from a
main (side circuit) door loudspeaker
to a free storey, i.e. several calls are
possible simultaneously.
If you require an additional internal
speech facility between the con-
nected in-house telephones at the
storey controller, a group controller
GC 612-… and in-house telephones
HTC 811-… (max. 6) must be used
in addition. In parallel with every
ETC 602-… it is possible to con
-
nect a switching/remote controller
SFC 602-… to the storey door
loudspeaker(s).
All calls have audio privacy.
When using the HTS 811-… no call
differentiation between the main
(side circuit) door loudspeaker and
storey door loudspeaker is possible!
Call differentiation HTC 811-…
at ETC 602-…
Main (side circuit) door call: 3-tone
call
Storey door call: 3-tone chime
Call differentiation HTC 811-… at
ETC 602-… with GC 612-…
Main door call: 3-tone chime
Storey door call: 1st and 2nd chime
tone of the three-tone chime, subse-
quently normal 3-tone chime
Internal call: 3-tone call
Function
After a completed call from a storey
door station, this remains switched
on at the called in-house telephone
for 30 seconds. If no receiver is lifted
during this period, the connected
in-house telephones on the storey
level are switched on again at the
main door station. Actuation of
the storey door release, the storey
light and the storey SFC 602-… is
only possible during a connec-
tion to the storey.
After replacing
the receiver, the telephones are
switched on again at the main
door loudspeaker(s) after around
10 seconds. Outside a storey call,
the door release and light relay of
the
last called main (side circuit)
door loudspeaker
and any con-
nected SFC/CTÖ 602-… are
always
actuated. The storey controller
ETC 602-… is fitted with a potential-
free switchover contact (WT/W0/
WE).
Summary of Contents for AS-Ta-64/1
Page 1: ...System Manual 1 n technology Issue 2013 ...
Page 7: ...7 ...
Page 16: ...16 5 Installation AS Ta 64 1 Siedle Vario Remarks Appliance requirement ...
Page 20: ...20 5 Installation AS Ta 64 1 Siedle Classic Remarks Buttons Appliance requirement ...
Page 22: ...22 5 Installation AS Ta 64 1 Siedle Steel Remarks Buttons Appliance requirement ...
Page 26: ...26 5 Installation AS Ta 64 2 Siedle Vario with 2 door stations Remarks Appliance requirement ...
Page 30: ...30 5 Installation AS Ta 64 3 Siedle Vario with 3 door stations Remarks Appliance requirement ...
Page 53: ...53 ...