5
For the entire conductor length
in the 1+n system, the following
applies:
with cable material YR or J-Y(St)Y
with 0.8 mm diameter
• max. 500 m/1640 ft between the
door station and the most distant in-
house telephone
• max. 100 m/328 ft between the
line rectifier and the most distant
door station
• max. 500 m/1640 ft core length
TLn between several door stations
With cable material YR or J-Y(St)Y
with 0.6 mm diameter
• max. 250 m/820 ft between the
door station and the most distant
in-house telephone
• max. 50 m/164 ft between the line
rectifier and the most distant door
station
• max. 250 m/820 ft core length
TLn between several door stations