125
Voltage mode output 23,24 (AC/
DC)
At the
output terminals 23,24
, it
is possible to configure direct cur
-
rent operation (DC) or alternating
current operation (AC) for the door
release during the programmed
door release time. In this case, syn
-
chronous or alternating voltage is
applied. The door releases must be
operated depending on their type
with either direct current (DC) or
alternating current (AC). When using
a different switching output with the
door release function, an external
voltage supply is required, as only a
potential-free switching contact is
available.
Doormatic
In the Doormatic area, define
whether the Doormatic function
should be capable of being activated
at this door/door station or not. If
the option
Doormatic can be acti-
vated
is active, devices will be able
to activate the Doormatic function
at this door/door station. If a device
can be called from this door/door
station with the Doormatic function
activated, the contact (door release)
configured as the door release is
actuated.
Procedure –
Configuring the door
station (ATLC)
1
Connect the ready wired Access
door loudspeaker controller (ATLC)
of the door/door station to the
Access network.
2
In the navigation area, click on the
Users
menu.
3
The
Users
menu opens up.
4
Click in the navigation area in the
opened
Users
menu on the folder
Not assigned devices
, in order to
open it.
5
The folder
Not assigned devices
is opened in the navigation area.
6
The door/door station is displayed
following detection by the Access
server in the menu
Users > Not
assigned devices
.
7
Drag&Drop the still unassigned
door/door station using the mouse
from the folder
Not assigned
devices
to the required position of
the
Project/folder structure
.
8
Click on the required door station
(
ATLC…
).
9
The page
Edit user: [door name]
opens in the content area.
10
Carry out all inputs in the
General
area.
11
Always assign meaningful names
and descriptions.
Note
• The fields
Call number
and
Assignment
are automatically
issued by the Access system and can
be edited at any time.
12
Check the
Call number
and
change it if required, for example to
implement your call number system.
13
Check the
Assignment
and
change/supplement it if required.
14
Leave the entered
MAC address
unchanged and change to the next
field.
15
The
hardware revision
is an
information field and cannot be
edited.
16
Set the
voice volume
in accord
-
ance with the assumed ambient
volume using the slide controller at
the door station (high volume for
loud environments).
17
Set the
microphone sensitivity
in accordance with the assumed
ambient volume using the slide
controller at the door station (high
microphone sensitivity with a large
gap between the speaker and the
door station).
Note
• For optimum setting of the voice
volume and the microphone sensi
-
tivity, you may have to carry out sev
-
eral tests during function testing.
18
Under
Camera available
, check
whether the information agrees with
this door/door station.
19
Leave the selection
Default
telephone script
unchanged under
Telephone script
if you do not wish
a secondary signal unit or a surveil
-
lance camera to be operated at this
door/door station. Otherwise select
the required telephone script.
20
Activate the option
Acoustic
button acknowledgement
, if you
wish every actuation of call button
at this door station to be audibly sig
-
nalled with a standard or individually
designed confirmation tone at the
loudspeaker of the door station.