background image

Manual
DoorCom IP

DCIP 650-0

Summary of Contents for DoorCom IP DCIP 650-0

Page 1: ...Manual DoorCom IP DCIP 650 0 ...

Page 2: ...supply 12 Interfaces power supply 13 5 Installation wiring diagrams DCIP 650 0 Terminals DCIP 650 0 14 LED signalling IPVS 600 15 Block diagram SIVS 610 0 16 Block diagram SII 650 0 17 AS diagram AS TVHa 1 1 18 Single line system with DCA 740 AS diagram AS TVHa 1 1 20 Multiple line system with DCA 740 AS diagram AS TVHa 1 1 22 6 Commissioning SIVS 610 24 SII 650 26 7 DoorCom Analog DCA 740 01 29 8...

Page 3: ...0950 The building installation must include an all pole mains switch with a contact separation of at least 3 mm Ensure that the connection point in the building installation is fused with max 16 A When planning the required distributor space for switch panel mounted devices must be taken into account External voltages 30 V AC DC must not be injected into the in house telephones Devices with 230 V ...

Page 4: ...e SIVS 610 The a b public network interface is supplied from the TC system It is not possible to connect an individual public network telephone directly to the a b line of the DCA 740 01 Functions Door call from the In Home bus and signalling Text display of which door or which bus telephone is calling Door release actuation Light actuation Direct dialling and connection to a door station or a bus...

Page 5: ... Home doors across lines and also to In Home telephones only IPVS 600 0 VNG 602 PRI 602 USB BVVU 650 BVVU 650 BVVU 650 telephone system In Home bus Video TCP IP Network within a line Doors and bus telephones can be selectively connected called Devices such as BSE 650 BSM 650 etc can be actuated across different lines but not bus telephones Capacity to manage up to 100 messages 100 functions Parall...

Page 6: ...cify which source is required for the multicast stream IWA Interface working address Six digit address with which the system interface video server e g SIVS IP 610 addresses the users LAN Local Area Network Local cable linked network Multicasting Term to denote group parallel calls with video image to several PC users which have the Software Client installed For this to be possible the UDP and IGM...

Page 7: ... and connected devices and their characteristics automatically detected Vario bus Various different input and control units can be connected to the Vario bus It comprises 4 cores The information on the Vario bus is transmitted via the RS485 protocol Web browser Software for the display and indication of Internet pages or corresponding configuration pages e g Internet Explorer or Firefox ...

Page 8: ...e bus 1 4 call buttons integrated LED lighting Connection via ribbon cable to the bus door loudspeaker Supply to the LED lighting via terminal b and c with 12 V AC current consumption 25 mA per bus call button module BTM 650 BCMC 650 Bus colour camera module for Siedle In Home bus Video Integrated 2 step heating day night switching infrared lighting and video signal converter Supply via Siedle In ...

Page 9: ...emperature 20 C to 70 C Dimensions 99 x 99 mm DRM 611 0 Display call module as an input unit with 4 line display for placing door calls To scroll through the name index there are two arrow keys provided for up down An external DR button can be connected Display showing 4 lines of 18 characters each with LED backlighting 3 displacement free piezo buttons Button actuation with acoustic confirmation ...

Page 10: ...dardized a b interface of a TC system analogue PBX extension or directly at the analogue telephone network Dimensions 107 x 89 x 60 mm IPVS 600 0 System interface video server Processing and adjustment of audio and video transmission of data audio and video to the IP network Dimensions 112 x 85 x 40 mm PRI 602 USB Programming interface for connection of a Windows PC via USB port to the In Home int...

Page 11: ...11 ...

Page 12: ...us Video for the SIVS 650 Dimensions 107 x 89 x 60 mm VNG 602 Video line rectifier in a 10 grid housing Primary 230 V AC 50 60 Hz Secondary 30 V DC 1 1 A stabilized For supply to the SIVS 610 and the connected interfaces BVNG 650 0 Bus video line rectifier in a 9 grid housing Primary 230 V AC 50 60 Hz Door release contact 15 V AC 30 V DC 2 A switching time fixed at 3 seconds Light contact 15 V AC ...

Page 13: ...C 600 0 DoorCom IP Software Client PC program which depicts a virtual in house telephone with video on a PC monitor Door communication with video to one or more door stations possible Implementing switching and control functions e g door release light switching or indication of messages on the PC monitor For each installation of the Software Client on a PC a licence is required for the DCIP SC 600...

Page 14: ...isting network connection g LED T flashes orange on data transmission via the network Terminals IPVS 600 0 h Video input 1Vss from the SIVS 610 i Audio line In to the SIVS 610 j Terminal plug for control signals i Audio line Out to the SIVS 610 Terminals SIVS 610 a Video signal 1 Vss cinch jack b Terminating resistor 75 Ohm ON OFF c IN video signal 1 Vss input D video signal 1 Vss throughput d Ter...

Page 15: ...ts to operating status ON ON The boot area is checked Software runs in the flash Fast flashing ON After a software update the boot area is recreated This can take up to around 3 minutes Operation LED green LED red Function ON OFF Booting is complete All OK Normal status Slow flashing OFF Display a connection exists Fast flashing OFF A software update or reconfiguration process is under way Fault L...

Page 16: ...E4 Input 3 not used E4 Input 2 not used E4 Input 1 not used cv Pick off supply voltage bv for Vario bus 15 V DC max 300 mA Da Db Vario bus Supply voltage 24 30 V DC DR Not used DR DR via TLC 640 02 Li not used USP Not used SN1 RF signal path SN2 SIM 740 to SIVS 610 n1 RF signal for connected n2 DCA 740 01 ...

Page 17: ...gnalling SII 650 The system interface In Home bus SII 650 is fitted with 2 LEDs under the device lid which display operating statuses and provide an indication of possible faults Switching on LED1 LED2 Function OFF ON Power On or Reset Device boots to operating status ON OFF Operating status display Slow flashing OFF Operating status display with active connection ON Fast flashing Variobus address...

Page 18: ... TbM ERT ERT TbM TbM TbM Sb Sb TbM TbM TbM TbK TaK Ta Ta c GND GND c c b Vc Vc b b Tö Tö Li Li N N N L1 L1 L1 TbK Tb Tb BCMC IN ERT ERT ERT Ethernet RJ45 SIVS 610 IPVS 600 cv Db SN2 bv Da SN1 LineIn LineOut VideoIn RS232 ETH f Video Link IP M1 IN SN2 GND SN1 cv Db bv Da S1 S1 E1 E1 M M PRI 602 USB BTCV 850 d e TaM TbM ETb ERT red black Device requirement Remarks input signal 4 30 V DC 10 mA 5 Inst...

Page 19: ...Up to 49 45 PC users are possible at one IPVS Reduction to 45 PC users can result if 10 or more PC users are configured as parallel devices Remarks a The TR 603 12 V AC 1 3 A can supply 1 door release button and max 24 bus call button modules with LED lighting BTM 650 01 02 03 and 04 With more than 24 illuminated bus call button modules an additional TR 603 is required Current consumers in the AS ...

Page 20: ...Ta c GND GND c c b Vc Vc b b Tö Tö Li Li N N N L1 L1 L1 TbK Tb Tb BCMC IN Ethernet RJ45 SIVS 610 IPVS 600 cv Db SN2 bv Da SN1 LineIn LineOut VideoIn RS232 ETH f Video Link IP M1 IN SN2 GND SN1 cv Db bv Da S1 S1 E1 E1 M M PRI 602 USB DCA 740 01 n2 n2 Db c n1 n1 Da b Lb La g Device requirement Remarks red black input signal 4 30 V DC 10 mA Analog telephone connection to TBR 21 5 Installation DCIP 65...

Page 21: ...utton and max 24 bus call button modules with LED lighting BTM 650 01 02 03 and 04 With more than 24 illuminated bus call button modules an additional TR 603 is required Current consumers in the AS diagram Door release appr 600 mA Camera heating 100 mA LED lighting Per bus call button module 25 mA b Door release contact load in the bus video line rectifier BVNG 650 max 15 V AC 30 V DC 2 A Light co...

Page 22: ...D c c b Vc Vc b b Tö Tö Tö Tö Li Li Li Li N N N N N L1 L1 L1 L1 L1 TbK Tb Tb BCMC IN Ethernet RJ45 Ethernet RJ45 SIVS 610 SIVS 610 IPVS 600 IPVS 600 cv cv Db Db SN2 SN2 bv bv Da Da SN1 SN1 LineIn LineIn LineOut LineOut VideoIn VideoIn RS232 RS232 ETH ETH f f Video Video Link IP Link IP M1 M1 IN IN SN2 SN2 GND GND SN1 SN1 cv cv Db Db bv bv Da Da S1 S1 S1 S1 E1 E1 E1 E1 M M M M PRI 602 USB Device re...

Page 23: ...45 PC users are possible at one IPVS Reduction to 45 PC users can result if 10 or more PC users are configured as parallel devices Remarks a The TR 603 12 V AC 1 3 A can supply 1 door release button and max 24 bus call button modules with LED lighting BTM 650 01 02 03 and 04 With more than 24 illuminated bus call button modules an additional TR 603 is required Current consumers in the AS diagram D...

Page 24: ...ect the menu point Service parameters Click the submenu Network On the right hand side the relevant settings are opened up The following settings can be performed for operation in the network IP address Subnet mask address Video transmission HTTP browser port Type of network connection Changes to the IP address or subnet mask address are transmitted to the device by clicking on the Set button Howe...

Page 25: ...ently transfer the configuration to SII 650 SIVS 610 Step 5 In the tree structure of the BPS 650 select the SII 650 Pressing the Configuration button in the DCIP SC will open a new window In this window it is possible to select which users are read out to the configuration being created In this selection process different configurations can be generated for different software clients Step 6 The se...

Page 26: ...ctX Version 9 0c Start the Software Client The Software Client configuration can be opened by pressing the right hand mouse button on the virtual in house telephone In the first tab Configuration select add DCIP SC file and import the file exported by the configuration software dcip It is then possible under DCIP SC Edit file to assign an IWA address to the Software Client for the relevant DCIP 65...

Page 27: ...off If there is an active firewall the application file DCIP SC 600 0 exe must be defined as an exception or as a permanently authorized program application In order to establish a video link it may be necessary for the drivers for the used graphic card to be updated to the latest status Other settings in the Software Client Free buttons Selection of functions for buttons 1 3 Each button can be as...

Page 28: ...28 ...

Page 29: ... 740 is supplied directly from the SIVS 610 A separate supply is consequently not required The power to the a b public network interface is supplied from the telecommunication system or the a b public network connection from the exchange It is not possible to connect an individual public network telephone directly to the a b line of the DCA 740 8 DoorCom IP Factory setting IPVS 600 With the reset ...

Page 30: ...o be measured using a digital multimeter Idle status min max Voltage at the SIVS 610 24 V DC 30 V DC Current consumption 500 mA Conductor lengths VNG 602 supplies 1 DCIP 650 100 m VNG 602 supplies 2 DCIP 650 50 m 9 Servicing Measured values ...

Page 31: ...ownload area under www siedle de Technical additions and printing errors do not constitute grounds for any claims to damages Terminals 14 Wiring diagram 18 As delivered status 29 Block diagram 18 Client 26 Config 24 DoorCom 10 Commissioning 24 IP 6 IP address 6 IWA 6 LED display 15 Licences 26 Line rectifier 12 Programming 24 Server 8 Software Client 26 Subnet mask 6 System interface video server ...

Page 32: ... 2008 12 10 Printed in Germany Best Nr 0 1101 237158 EN S Siedle Söhne Postfach 1155 D 78113 Furtwangen Bregstraße 1 D 78120 Furtwangen Tel 49 7723 63 0 Fax 49 7723 63 300 www siedle de info siedle de ...