5
Prior to commissioning the
DoorCom IP, the entire In-Home
system must be programmed.
The components SII 650-...,
SIVS 610-... and BVNG 650-... which
are in the same line must have the
same address set. Programming
of the SIVS 610-... and SII 650-...
takes place with bus programming
software BPS 650-...
No programming is required for the
DCA 740-01. For programming and
configuration of the TC system, see
the relevant product information
and programming instructions of the
manufacturer.
Performance features
DoorCom IP 650-...
• Transfer of door calls with/without
video
• Audio transmission possible via the
telephone network (DCA 740-...)
• Actuation of the door release and
light.
• Selective connection to a door
station. (Audio and/or video)
• Speech connection is possible both
to In-Home doors (across lines) and
also to In-Home telephones (only
IPVS 600-0
VNG 602-...
PRI 602-... USB
BVVU 650-...
BVVU 650-...
BVVU 650-...
telephone system
In-Home-bus: Video
TCP/IP-Network
within a line)
• Doors and bus telephones can be
selectively connected / called
• Devices such as BSE 650-...,
BSM 650-... etc. can be actuated
across different lines. (but not bus
telephones)
• Capacity to manage up to
100 messages / 100 functions
• Parallel calls (bus telephones and
SII users) are possible
• Pure video connections can also be
established to the In-Home bus
• Communication to the SIVS 610-...
takes place via the bidirectional SUS
interface with the Vario bus protocol
• Programming takes place via the
SUS interface and via the
USB-PRI 602-...
• Firmware update possible via the
SUS interface
• The address setting for connection
to the Vario bus takes place via a
BCD rotary encoding switch
• Max. 31 users possible per
DCIP 650-... .
Autocommunication via the telephone system