background image

27

Index 

Accessibility of the Gateway

11

App

19

As-delivered status

24

Automatic logout

4

Backing up/ 

Restoring the system

26

Basic functions

10, 15

Bus address reference

18

Bus addresses in  

the In-Home bus

25

Bus line

7, 8

Call number prefixes

20

Carry out a function check

24

Carry out the update

16

Change user profile / password

17

Check/change the network 

settings

17

Commissioning  

requirements

13, 14

Commissioning software

13

Configuration data

26

Creating IP groups

18

Date / time

17

Debug

26

DHCP server

 – Changes

24

Direct LAN connection

11

Door call option settings

17

Downloading and installing the 

bus programming software

14

Electrical voltage

4

Emergency

26

Error

26

Function licences

25

Functions applicable  

across individual lines

7

Import bus configuration

19

Import licences

25

Indirect LAN connection  

with active DHCP server

11

Indirect LAN connection  

with inactive DHCP server

12

Info

26

Integrable networking 

 

components

5

IP address and password reset

24

IP users

5, 8, 18, 25

Jung TKM Client

5

Legal notice

4

Licences

25

Local access points

13

Log level

26

Logging

26

Login on the 

Gateway

12, 16, 18, 22

Manual programming

10, 15

Menu structure User interface

9

Mobile network connection

21

Multiple line system

8

Network characteristics

13

Observe the safety instructions!

4

Operating software/apps

13

Operational data

26

Optional commissioning steps

25

Performing a system update

16

Possible IP clients

5

Preparation

9

Programming using the PC and 

bus programming software 

(BPS 650-…)

16

Protect your network!

4

Protect your property!

4

Register product

14

Required documentation

13

Required hardware

13

Reserving bus addresses

25

Reset button

24

Resetting the system

24

Restarting

24

Restarting the Gateway

24

Servicing

4

Setting the door call

17

Setting video memory/door call

17

Siedle app

19

Siedle Axiom

19, 20

Single line system

7, 8

Step-by-step through the 

 

commissioning process

14

Storey call –  

Defining IP users/IP group

18

System limits

8

System overview

5

Time setting

13

Trace

26

Use of at least 2 but no  

more than 15 bus lines

8

Use of one bus line

8

User licences

25

Video memory settings

17

Warning

26

Summary of Contents for SG 650-0

Page 1: ...SG 150 0 Commissioning instruction Smart Gateway ...

Page 2: ...er product 14 Downloading and installing the bus programming software 14 Commissioning Manual programming 15 Programming using the PC and bus programming software BPS 650 16 Performing a system update 16 Change user profile password 17 Setting the date and time 17 Check change the network settings 17 Setting video memory door call 17 Video settings 17 Creating IP users 18 Deleting IP users 18 Crea...

Page 3: ... Gateway in the In Home bus and exporting the configuration 10 Login on the Gateway 16 Performing a system update 16 Change user profile password 17 Setting the date and time 17 Check change the network settings 17 Setting video memory door call 17 Import In Home bus configuration 19 Creating IP users Creating IP groups 18 Storey call Defining IP users IP group 18 Registering IP users 18 Set up th...

Page 4: ... repair sale exchange uninstall the app from this device Never hand over an smartphone with an operable app to a third person Delete the affected IP user from the Gateway This ensures that the affected IP user no longer has access to the door station In case of emergency Pull the network cable out of the LAN connection of the Gateway or Deactivate the WLAN of the WLAN router Block any existing ext...

Page 5: ...xiom Overview BVNG 650 Siedle intercom system building installation Door station WLAN SG 150 Mobile phone with installed Siedle app for Smart Gateway WLAN Internet SG 150 ERT ETb TbM S1 S1 E1 E1 PE PE TaM 0000000000000 Smart Gateway SG 150 0 IP 20 www siedle com Link In Home Status Reset Prog ERT ETb TbM S1 S1 E1 E1 PE PE TaM 0000000000000 Smart Gateway SG 150 0 IP 20 www siedle com Link In Home S...

Page 6: ...esses 25 Programming the In Home bus manually or using the bus programming software 10 Export the In Home bus configuration from the bus programming software 18 Import the In Home bus configuration 19 Install the software Siedle app on the terminals mobile phone and log in at the Gateway 19 22 Mobile network connection 21 Carry out a complete function test and hand over the documentation files to ...

Page 7: ...dual functions are not available for technical reasons Functions applicable across individual lines Door calls selective door dialling and switching and control functions can also be used across individual lines Internal speech communication and call forwarding between users is only possible within a line Connection of bus and IP address If you are operating the Siedle intercom and the Gateway in ...

Page 8: ...n entrance 2 Door call station Side entrance 2 Internal call station 1 1 Internal call station 2 1 Gateway 1 Sum 7 Max number of bus addresses per bus line 31 Additionally usable free bus addresses 24 The result A maximum of 25 bus addresses can be used in the Smart Gateway for the connec tion of IP users or IP groups 24 free bus addresses 1 already assigned bus address of the Smart Gateway System...

Page 9: ...e Change the password Basic settings Date time Network Video memory Door call Video Call number prefixes In Home bus Bus adresses Bus users Network user Licences IP users IP groups Telephony link Help Documentation Commissioning software Support System Protocols Safe Restore Update Reset Restarting Log out Preparation ...

Page 10: ...le at the Gateway When carrying out manual programming you can assign only one bus address to the Smart Gateway to allow either an IP user or an IP group to be selectively called If this is not ade quate you must carry out program ming using the bus programming software If you decide in favour of manual programming the steps with bus programming software are omitted Remarks on the Finder function ...

Page 11: ...ting network router wireless LAN router managed switch server The network setting of the Gateway is in the as delivered status DHCP client active The DHCP client is enabled on your commissioning Laptop PC to be able to request a network address from the DHCP server router wire less LAN router managed switch server Remarks In the delivery status the Gateway is delivered with an active DHCP client a...

Page 12: ... a different language 5 Enter the user name admin 6 Enter the relevant password standard admin 7 Click on Log in 8 The administrator user interface of the Gateway appears 9 Click on Basic settings Network 10 The network settings are dis played 11 Remove the tick under Obtain IP address automatically by DHCP 12 The network settings are now highlighted in white and can be changed 13 Execute the chan...

Page 13: ...te then the time must be reset after each power failure or reset as there is no buffer battery Alternatively you can operate the Gateway with manual time setting at an uninterruptible power supply Sufficient number of user licences For each IP user Siedle app etc one user licence is required There are 5 user licences contained in the scope of supply Other user licences can be ordered under www sie...

Page 14: ...require the MAC address hardware address of the Gateway e g 00 10 20 30 a1 b2 The MAC address of the Gateway can be found on the packaging on the device sticker and in the device information of the browser based user interface Procedure 1 Register your Gateway on the mysiedle service portal 2 Download existing system updates and save these on your commis sioning laptop Downloading and installing t...

Page 15: ...d down the light programming button for 4 seconds A protracted acknowl edgement tone is then audible which is repeated every 5 seconds as long as the programming mode remains active 1 Switch on the programming mode At the BNG BVNG 650 press the programming mode button briefly The LED 1 flashes in a 2 second rhythm to indicate that the program ming mode is active 4 On the door station press and hol...

Page 16: ...C before every system update The system update only affects the Gateway and the connected hard ware Update via local update tool Procedure 1 To access the latest software update please download the update tool from www siedle de sg 150 2 Save the file with the extension exe to your hard drive 3 Activate the installation process by double clicking and run the tool 4 Confirm any pop up queries about...

Page 17: ...eo memory and door call Both setting ranges are visually separated by a frame Procedure 1 Click on Basic settings Video memory door call Video memory settings 2 Activate the automatic video memory if you wish an image to be taken of the person calling after every door call 3 Activate the manual video memory if you wish users of the Siedle app to be able to manually take additional images 4 Set the...

Page 18: ...er 6 Select the IP users for the IP group by clicking on Add and confirming your selection with Close 7 Save the IP group by clicking on Save Storey call Defining IP users IP group The call button for the storey call is connected directly at the Gateway terminal ERT and ETb and is there fore independent from the rest of the In Home bus A door call via the storey call is processed directly in the G...

Page 19: ...t the Siedle App on your smartphone and log in using the login data QR code assigned in the Gateway For successful login both devices must be connected to the Internet Always use the latest version of the Siedle app Commission the Siedle app 1 Install the Siedle App on your Smartphone You can obtain the Siedle App from the App Store or Play Store 2 Create a new IP user Siedle App in the Smart Gate...

Page 20: ...C system if required 11 When logging in with SIP client enter the user authentication speci fied by the TC system if required 12 Select the supported DTMF mode 13 If required define a call number prefix 14 Click on the Apply button Commissioning Link Siedle Axiom Procedure 1 Create the Siedle Axiom in the Gateway as an IP user 2 Under Network users Telephony connection open the SIP client that you...

Page 21: ...Commission the Siedle app 6 Complete function check Sequence Install the mobile network connection ERT ETb TbM S1 S1 E1 E1 PE PE TaM 0000000000000 Smart Gateway SG 650 0 IP 20 www siedle com Link In Home Status Reset Prog Infographic Connecting a Mobile Terminal to a Smart Gateway Internet Router Siedle Server Mobile WLAN Door station Indoor station Siedle App Smart Gateway QR Code ...

Page 22: ...ection with static or dynamically changing public IP address Download The frame rate number of frames per second of the transmitted video stream from the Siedle Server to the Siedle App depends on the data transmission rate that is available for the mobile network connection at the time of the door call Bandwidth 2 MBit s approx 5 frames second are shown Bandwidth 4 MBit s approx 10 frames second ...

Page 23: ...Siedle app Mobile internet connec tion IPv4 connection Public IP static or dynamic Download see page 22 Upload constant 512 kBit s Stable WLAN or mobile phone connection 3G 4G 5G SIP VoIP enabled Provider Download constant at least 512 kBit s Upload see page 22 SIP VoIP enabled Public IP static or dynamic WLAN LAN In Home bus Infographic Mobile phone network requirements 3G 4G 5G ...

Page 24: ... Reset 2 Click on Restore as delivered status in order to reset the Gateway 3 In response to the confirmation prompt click on Yes if you wish to reset the Gateway Restarting the Gateway If the IP settings have been changed in the IP network with DHCP oper ation the Smart Gateway has to be restarted A restart corresponds to switching the power supply to the Smart Gateway off and on again After a re...

Page 25: ...line rectifier and end it after 2 seconds at the earliest 10 The reserved In Home bus address es has have been assigned to the Gateway and can be used for programming configuring the In Home bus 11 Repeat the steps for program ming with PC and Bus programming software BPS 650 Licenses User licences There are 5 user licences for IP users contained in the scope of supply For each IP user you wish to...

Page 26: ...system update Procedure 1 Click on System Protocols 2 Click the download icon to save the reqired log file Backing up Restoring the system In the Gateway you can back up and restore the configuration data the operating data or also both together After completion of the successful function test back up the whole system and hand the files to the cus tomer system administrator During a system restore...

Page 27: ...d reset 24 IP users 5 8 18 25 Jung TKM Client 5 Legal notice 4 Licences 25 Local access points 13 Log level 26 Logging 26 Login on the Gateway 12 16 18 22 Manual programming 10 15 Menu structure User interface 9 Mobile network connection 21 Multiple line system 8 Network characteristics 13 Observe the safety instructions 4 Operating software apps 13 Operational data 26 Optional commissioning steps...

Page 28: ...elefon und Telegrafenwerke OHG Postfach 1155 78113 Furtwangen Bregstraße 1 78120 Furtwangen Telefon 49 7723 63 0 Telefax 49 7723 63 300 www siedle de info siedle de 2017 11 19 Printed in Germany Best Nr 210009601 00 EN ...

Reviews: