8
Example – Multiple line system
Use of at least 2 but no more than
15 bus lines.
Installation example
The Siedle call station comprises
2 door stations (main and side
entrance),
2 indoor stations (storey 0
and 1), 1 Gateway and 2 bus vid
eo
line rectifiers.
The Siedle intercom is supplied via
the first bus line and the Gateway
via the second bus lin
e.
Calculation
of the additional bus addresses
which can be used in the Gateway:
1. Bus line
Components
Bus
adresses
Door call station Main
entrance
2
Door call station Side
entrance
2
Internal call station 1
1
Internal call station 2
1
Sum
6
Max. number of bus
addresses per bus line
31
Additionally usable free
bus addresses
25
2. Bus line
Components
Bus
adresses
Gateway
1
Max. number of bus
addresses per bus line
31
Additionally usable free
bus addresses
30
The result: A maximum of 31
bus addresses can be used in the
Gateway for the connection of
IP users or IP groups (30 free bus
add 1 already assigned
bus address of the Gateway).
Example – Single line system
Use of one bus line
.
Installation example
The Siedle call station comprises
2 door stations (main and side
entrance),
2 indoor stations (storey 0
and 1), 1 Gateway and 1 bus vid
eo
line rectifier.
Calculation of the additional bus
addre
sses which can be us
ed in the
Gateway:
1. Bus line
Components
Bus
adresses
Door call station Main
entrance
2
Door call station Side
entrance
2
Internal call station 1
1
Internal call station 2
1
Gateway
1
Sum
7
Max. number of bus
addresses per bus line
31
Additionally usable free
bus addresses
24
The result: A maximum of 25
bus addresses can be used in the
Smart G
ateway for the connec-
tion of IP users or IP groups (24
free bus add 1 already
assigned bus address of the
Smart
Gateway).
System limits
Gateway
Characteristics:
Number
Maximum number of
assignable bus addresses
31
Maximum number of IP
users p
er Gateway (the
scope of supply of the
Gateway includes 2 us
er
licences for a total of 2 IP
users)
50
Maximum number of IP
groups
–
Maximum number of IP
users per IP group
6
Cascading: IP group in IP
group
0
With an In-Home bus address, you
can:
Selectively call 1 IP user individually
through the In-Home bus (
e.g. door
station)
or
Selectively call 1
IP group (with a
ma
ximum of 6 IP users)
individually
through the In-Home bus (e
.g. door
station).
With 31 In-Home bus addresses,
you can:
Selectively call 31 IP users individu-
ally through the In-Home
bus (e.g.
door stat
ion)
or
Selectively
call 31 IP groups (w
ith a
maximum of 6 IP users) individuall
y
but in total no mo
re than 50 IP users
per Gateway through
the In-Home
bus (e.g. door station)
or
•
In a mixed configuration with a
maximum
of 50 IP users, sele
ctively
call individual IP users or IP groups
(with a maximum of 6 IP users)
through the In-Home bus
(e.g. door
station)