Element-MF Stove
25
CAUTION: Operate this unit only with the fuel hopper lid closed. Failure to do so may result in
emission of products of combustion from the hopper under certain conditions. Maintain hopper
seal in good condition. The auger will be prevented from operating by a hopper lid switch. Close
lid immediately after filling hopper with fuel.
INSTALLATION CHECK
Proper installation is essential for Safety, effective Operation, Warranty Coverage, Insurance
requirements and to meet Local Building Codes. Installation Requirements are described in the first
section of this manual. Verify the installation is correct before firing up the Element-MF for the first
time.
When burning corn, wheat or rye, care should be taken in how the venting system is installed. To burn
corn, wheat or rye the moisture content should be 15% or less. This is much higher than the moisture
content of wood pellets and can result in condensation forming in the venting system in certain
installations. The chimney system should stay within the warm envelope of the house as much as
possible. Only penetrate the exterior of the home where the exhaust system will terminate.
REMEMBER: Condensation from burning Corn, Wheat, Rye or Distillers Grain Pellets is
detrimental to the venting system. Only buy Venting Systems that are warranted with burning
corn.
PREVENTING CHIMNEY FIRES
Chimney fires can be prevented by properly operating the Element-MF and by periodic inspection and
cleaning of the chimney. When wood is burned it produces tar and other organic vapors, which
combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool
chimney flue associated with a slow burning fire. As a result, creosote residue accumulates on the flue
lining. When ignited, this creosote can result in an extremely hot chimney fire.
The chimney and chimney connector should be inspected at least once every two months during the
heating season to determine if a creosote build-up has occurred. If a significant layer of creosote has
accumulated (3 mm or more) it should be removed to reduce the risk of a chimney fire. Use of an
appropriately sized chimney brush or the services of a professional chimney sweep are recommended.
The chimney and chimney connector should be inspected at least once every two months during the
heating season to prevent the system from getting plugged with Fly ash. Clean the exhaust system if
needed. Use of an appropriately sized chimney brush or the Services of a Professional chimney sweep
are recommended.
Element-MF Operation
Summary of Contents for Element-MF
Page 56: ...Element MF Stove 56 Figure 37 Element MF Parts ...
Page 57: ...Element MF Stove 57 Figure 38 Element MF Parts ...
Page 58: ...Element MF Stove 58 Figure 39 Element MF Parts ...
Page 59: ...Element MF Stove 59 Figure 40 Figure 41 Element MF Parts ...
Page 60: ...Element MF Stove 60 Sensor System Figure 42 Figure 43 Figure 44 Element MF Parts ...