Element-MF Stove
53
Use Caution when touching the sensor. It may knock the sensor out of alignment.
When cleaning the sensor,
never use alcohol
or it will cloud the plastic lens. This will cause
the sensor to fail over time. A soft dry cloth is best.
8.
I turned the Stove on with the On/Off switch and nothing happens.
First check to see if the
Stove is plugged in and the receptacle has power to it.
Solution:
Check the fuse on the back of the control board. Replace with a 125 Volt, 5 Amp
fuse.
9.
Why is my glass dirty?
Normal operation of your St. Croix Stove will produce a light build-up
on the glass that wipes off with a dry paper towel. However extended burning on the low setting
only will produce a tan color. These types of build-up on the glass are normal. A heavy black
build-up on the glass could indicate a problem.
Solution:
Adjust the combustion air damper or combustion fan voltage. If this doesn’t seem
to help, make sure the clean out cover plates are installed in the Stove. It also
could be an indication that the Stove is getting plugged and needs a good
cleaning. Refer to the section in the manual that covers the Daily, Periodic and
Yearly Maintenance of the Stove.