Greenfield Installation and Operations Stove
Page 37
2 - Continuous burning of the Stove at the High burn setting (#5) –
Drop the Clinker
approximately every 12-18 hours
. This may vary depending on the quality of Fuel used.
Figure 23
The Daily Maintenance will mainly focus on 4 areas in the Greenfield; removing the clinkers
from the ash pan (if needed), dropping the clinker from the burnpot, cleaning the heat exchange
tubes and cleaning the glass. A breakdown of this process consists of the following steps:
Figure 24
The Coal Rake & the Slide-Out bottom must be in the correct position for the unit to operate correctly.
The Coal Rake must be pulled out or the burn pot will overload.