Greenfield Installation and Operations Stove
Page 40
Periodic Maintenance
CAUTION:
Periodic maintenance should only be done while the Stove is shut off and cold.
1.
Ashpan.
Empty the ash pan when it appears full (approximately once a week). The
frequency of cleaning the ash pan will depend on the quality and amount of fuel being used.
Carefully check to make sure the ash pan door is tightly closed after each opening.
2.
Burnpot and Slide-Out Bottom.
Clean burn grate holes whenever needed. Remove the
Burnpot and use a small metal object (Nail, Drill Bit, etc.) to clean out plugged holes. (
See
Figure 27 below).
Figure 27
Burnpot & Slide-out Bottom Removal
To remove the Burnpot from the Stove the Coal Rake must be pulled back so the pot will clear it.
Open the Firebox door of your Stove and you will see 2 Hex head screws. Loosen the first screw
enough to allow the Coal Rake to slide out of the burn pot. Remove the screw that holds the burn
pot in place and lift the pot out of the Stove. To access the Slide-out Bottom, remove the lower
panel and slide the bottom out of the Stove.
3.
Clean-Out Ports.
The Greenfield has 2 Exhaust Cleanout Ports located in the LEFT AND
RIGHT lower corners of the firebox. Remove covers and clean regularly.
There is an additional Cleanout behind the Ashpan. This cleanout gives access to the
transition area behind the back wall all the way back to below the Combustion Fan. If the
stove seems plugged, this area needs cleaning.