A certain amount of carbon monoxide may be produced within the Stove as a by-product of
combustion. All exhaust vent connections must be sealed with
RTV silicone
to assure a gas tight
seal.
Any leaks into a confined area caused by faulty installation or improper operation of
the Stove could produce dizziness, nausea and in extreme cases, death.
The CO
concentration in the flue gas during the Hastings testing was 11.31 g/hr. The Greenfield is a
“Non-Affected Facility” and was not tested.
3. WARNING: The high temperature paint on this Stove may take several hours of burning at a
high fuel setting to cure fully. During this time, an odor that is not harmful may be evident.
When odors are present, the area around the Stove should be well ventilated.
4. Caution: The high temperature paint can be easily scratched prior to burning the Stove.
5. Have your dealer demonstrate all the operational and maintenance steps necessary for proper
use of the Stove.
Sign and return the warranty card
to the address listed on the back page.
6. Some odors may be given off during the first few hours of burning during initial break-in.
These odors are normal and not harmful. However, ventilating the room until the odors disappear
is recommended.
7. The Stove will become HOT while in operation. Keep clothing and furniture away from all hot
surfaces.
8. To avoid the possibility of smoke and/or sparks entering the room always keep firebox and ash
pan doors closed whenever the Stove is operating. Smoke detectors, installed in the same general
area as the Stove, may be activated if the Stove door is left open and smoke is allowed to enter
the area.
9. Under certain circumstances an outside source of combustion air may be needed and is
required on all mobile home installations. Use only approved parts. When using outside air for
combustion, check that the outside air inlet is connected to draw fresh air from outside the
building. If room air is used to supply combustion air, room air starvation (not enough make-up
air), operation of exhaust fans and icing of air vents can adversely affect proper Stove operation.
This Multi-Fuel heater has a manufacturer-set minimum low burn rate that must not be altered. It
is against federal regulations to alter this setting or otherwise operate this Multi-Fuel heater in a
manner inconsistent with operating instructions in this manual.
CAUTION:
FAILURE TO FOLLOW THE INSTRUCTIONS IN THE INSTALLATIONS
MANUAL MAY RESULT IN A HOUSE FIRE, PROPERTY DAMAGE, BODILY
INJURY,
OR
EVEN
DEATH.
PLEASE
FOLLOW
INSTALLATION
AND
MAINTENANCE INSTRUCTIONS.
CAUTION: NEVER ADD FIRE STARTER TO A HOT STOVE.
CAUTION - Hot Surfaces
- Keep Children away.