Prescott Series Installation Manual
Page 7
Venting size Guidelines
Type of Installation:
Size:______________
A.
Less than 10’ horizontal:
3”
Acceptable
B.
10’ to 12’ horizontal:
3” or 4”
Acceptable
C.
Over 12’ horizontal:
4”
Required
(A horizontal installation over 12’ is NOT RECOMMENDED)
D.
Less than 15’ vertical:
3”
Acceptable
E.
Over 15’ vertical:
4”
Required
F.
Above 4000’ elevation:
3” or 4”
Acceptable
Note: Four (4) inch vent may be used in all installations. If in doubt, use 4” vent.