Prescott Series Installation and Operation Manual
Page 23
Mobile Home Installation
Unit must be installed in accordance with the:
Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24
Unit may be installed in a Mobile Home, after the initial sale of the Mobile Home. Not for
use in Recreational Vehicles.
Figure 17
1. WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
2. WARNING: COMBUSTION AIR MUST COME FROM THE OUTSIDE OF THE
MOBILE HOME! FAILURE TO DO SO MAY CREATE NEGATIVE PRESSURE
WITHIN THE MOBILE HOME AND COULD DISRUPT PROPER VENTING AND
OPERATION OF THE PELLET STOVE.
3. CAUTION: THE STRUCTURAL INTEGRITY OF THE FLOORS, WALLS, CEILING
AND ROOF MUST BE MAINTAINED.
4. Permanently bolt the stove to the floor, (X).
5. Electrically ground the stove and pedestal to the metal chassis of the home. Use a number
eight, (8) gauge or larger copper wire, (Y).
6. Maintain an effective vapor barrier at location where PL vent exits the structure.
7. Check any other local building codes or other codes that may apply.
8. Do not use components other than those specified for use with this unit.
9. Floor protection requirements must be followed precisely.
10. PL Vent must be used for exhaust venting. (Single wall vent is not allowed). Follow PL
Vent manufacturer’s installation directions and observe all listed clearances to combustibles.