Prescott Series Installation and Operation Manual
Page 45
8.
Are there any adjustments that can be made to the amount of fuel that is fed into the
burnpot?
Answer: There are several ways to adjust the amount of fuel that is
fed into the burnpot. The feedrates can be fine-tuned while the
Stove is in operation by
pressing and holding
the “Auger Feed”
button down and then
either
pressing the “Heat Level High” button
to advance the feedrate higher,
or
pressing the “Heat Level Low”
button to decrease the feedrate.
There are 5 levels on the control board and they are indicated by a
single flash of the LED’s. The default setting is the center LED.
This gives 2 adjustments increasing the feedrate (LED’s 4 & 5)
and 2 adjustments decreasing the feedrates. (LED’s 1 & 2) The ON
time is
increased or decreased
.25 seconds with each adjustment.
Figure 28
9.
Are there any adjustments that can be made to the
Combustion Fan voltages to help adjust the draft?
Answer: The Draft can be adjusted in a similar fashion as
mentioned in the previous example.
The Fan voltages can be fine-tuned while the Stove is in operation
by
pressing and holding
the “Auger Feed” button down and then
either
pressing the “Trim High” button to advance the voltages
higher,
or
pressing the “Trim Low” button to decrease the fan
voltages.
There are 5 levels on the control board and they are indicated by
single flash of the LED’s. The default setting is the bottom LED.
This gives 5 adjustments increasing the voltage (LED’s 2 through
5) The voltage is
increased or decreased
2.5 volts with each
adjustment.
Figure 29