SAFETY NOTICE: The stove must be properly installed in order to prevent the possibility
of a house fire! These installation instructions must be strictly observed! Failure to follow
instructions may result in property damage, bodily injury or even death.

The stove’s exhaust system works with negative combustion chamber pressure and a
slightly positive chimney pressure. Therefore, it is imperative that the air intake and
exhaust system be airtight and installed correctly. Do not install a flue damper in the
exhaust vent of this unit.

Do not connect this unit to a chimney flue serving another appliance or to any air distribu-
tion duct or system.

BUILDING PERMIT

Contact the local building officials to obtain a permit and information on any local instal-
lation restrictions and inspection requirements.

DEFINITION OF “STOVE”

The word “stove” as used in this manual is interpreted to mean a wood pellet burning
freestanding stove, insert, or zero-clearance fireplace unless otherwise noted.

SAFETY TESTING

The stove has been independently tested and listed by Warnock Hersey Laboratories in
accordance with the proposed ASTM Standards and the applicable portions of UL 1482
and ULC S627/B366.2, and Oregon Administrative Rules 814-23-901 through 814-23-
909, stating requirements for installation as a stove, heater or hearth insert for masonry,
metal and zero clearance fireplaces and for mobile home installations. The safety listing
label is located inside the right-side access panel.

DISCLAIMER OF WARRANTY

Since Even Temp Company has no control over the installation of a stove, Even Temp
Company grants no warranty, implied or stated, for the installation of a stove and as-
sumes no responsibility for any special, incidental or consequential damages.

1

Summary of Contents for York Insert

Page 1: ...ns 3 Exhaust Venting 4 Venting Approved Materials 4 Venting Determining Materials 6 Venting Stove Dimensions 7 Venting Through Combustibles 11 Venting Into an Existing Chimney 13 Venting Termination Requirements 15 Combustion Air 17 Electrical Connections 18 Floor Protection 19 ClearancestoCombustibleMaterials 20 MobileHomeInstallation 22 ThermostatInstallationandOperation 24 Notes 25 ...

Page 2: ...al lation restrictions and inspection requirements DEFINITION OF STOVE The word stove as used in this manual is interpreted to mean a wood pellet burning freestanding stove insert or zero clearance fireplace unless otherwise noted SAFETY TESTING The stove has been independently tested and listed by Warnock Hersey Laboratories in accordance with the proposed ASTM Standards and the applicable portio...

Page 3: ... by at least 3 screws and correctly installed Follow vent manufacturer s instructions 3 Any plated areas should be cleaned thoroughly with a glass cleaner such as Windex and a soft cloth just before lighting the first fire This will remove finger prints and oils that may cause a permanent stain or mark on the gold plating the first time it is heated Never use an abrasive cleaner or material on any...

Page 4: ... are approved for Conventional and Mobile Home installations as 1 A FREESTANDING stove on an approved floor pad or as a Hearth Mount stove 2 A FIREPLACE Insert when installed on the Hearth in a masonary or Zero Clearance type Fireplace 3 ...

Page 5: ... Simpson DuraVent and Selkirk Metalbestos and is carried by many local pellet stove dealers In this manual approved venting will be referred to a PL vent or Single wall vent All single wall vent adaptors must be stainless steel NOTE TYPE B GAS VENTMUSTNOTBE USED INANYPELLET STOVE INSTALLATION Examples of venting system components follow High temperature ceramic roping reduces potential fly ash esc...

Page 6: ...RAIN CAP WALL THIMBLE CHIMNEY SUPPORT VERTICAL OR ADAPTER BRACKET HORIZONTAL ADJUSTABLE SINGLE TEE SINGLE REDUCTION TEE DOUBEL TEE LENGTH W TEE CAP W TEE CAP W TEE CAP PIPE PIPE ADAPTER INCREASER 45 DEGREE 90 DEGREE ELBOW ELBOW 5 ...

Page 7: ...TURER S SAFETY SPECIFICATIONS QUANTITY OF MATERIALS 1 It is recommended that the vent system be installed with a minimum of three feet 3 of vertical rise above the stove exhaust port FAILURE TO PROVIDE THE NATURAL DRAFT THAT RESULTS FROM A VERTICAL RISE MAY RESULT IN SMOKE BEING RELEASED INTO THE HOUSE WHEN ELECTRICITY TO THE UNIT IS INTERRUPTED WHILE BURNING OR SMOLDERING PELLETS REMAIN IN THE BU...

Page 8: ...NDED D Less than 15 vertical 3 Acceptable E Over 15 vertical 4 Required F Above 4000 elevation 4 Recommended Note Four 4 inch vent may be used in all installations If in doubt use 4 vent A Width of stove B Height of stove C Center of exhaust tube from floor D Center of intake tube from floor E Center of stove to center of intake tube F Center of stove to center of exhaust Afton Bay dimensions 7 ...

Page 9: ...h of stove D Center of intake tube from floor B Height of stove E Center of stove to center of intake tube C Center of exhaust tube from floor F Center of stove to center exhaust tube Prescott EX Dimensions 8 ...

Page 10: ... of stove D Center of intake tube from floor B Height of stove E Center of stove to center of intake tube C Center of exhaust tube from floor F Center of stove to center exhaust tube Prescott EXL Dimensions 9 ...

Page 11: ...York Insert Dimensions 10 ...

Page 12: ...ar D Stove Exhaust Pipe L Rain Cap E Air Intake Damper M Outside Air Pipe F Air Vent Damper N PL Vent Section G 90 degree elbow O Wall Band H 45 degree elbow P Outside Air Inlet Cover 1 PL vent may be installed directly through a combustible wall ceiling or roof according to PL vent manufacturer s instructions See Figures 2 and 3 2 The PL vent system must be properly sealed and secured as per PL v...

Page 13: ...exhaust system under the house eaves Figure 4 the end of the vent pipe system must be at least twelve inches 12 from the wall and 24 below the eave a 90 degree G and a 45 degree elbow may be used H 2 When extending through the roof Figure 5 install a PL vent fire stop I in the ceiling or in the eaves if the eaves are boxed in Install roof flashing J and a storm collar K Extend the PL vent at least...

Page 14: ...mney chase cap which reduces the outlet of the chimney to the size of the reliner is required Extend the exhaust vent above the chimney chase cap and finish it off with a rain cap A single wall reliner must be insulated to maintain adequate exhaust temperatures when outside temperatures drop below freezing Figure 6 Figure 7 Venting into Masonry Chimney Venting into Class A Chimney 3 Venting into t...

Page 15: ...t T PL Tee or Single Wall Tee U Chimney Case Cover V Combustion Air Pipe W Combustion Air Shield Figure 8 Venting to the Top of Chimney 1 When installing as a hearth mount stove into a fireplace the unit must be relined and must terminate above the chimney chase top An approved flex liner of PL vent must be used 14 ...

Page 16: ...ion of adjacent structures and any code requirements 1 Exhaustmustterminateabovecombustionairinletelevation 2 Do not terminate vent in any enclosed or semi enclosed area i e Carports garage attic crawl space etc or any location that can build up a concentration of fumes 3 Ventsurfacescangethotenoughtocauseburnsiftouchedbychildren Non combustibleshielding or guards may be required 4 1 2 m BELOW a d...

Page 17: ...public walkway 1 305 mm FROM The wall penetration point 2 610 mm FROM any adjacent combustibles such as Adjacent buildings fences protruding parts of the structure roof eaves or overhangs plants shrubs etc FIGURE 10 VENTING TERMINATION CLEARANCE REQUIREMENTS SIDE VIEW All dimensions show MINIMUM distances 16 ...

Page 18: ...de air pipe diameter to 3 for runs over ten 10 feet and elevation over 4 000 feet Note Long runs should be avoided 4 Terminatetheoutsideairpipebelowtheexhaustventoutlet 5 An open mesh screen should be placed over the outside air pipe opening to prevent birds or rodents from nesting in the opening Use an elbow or shield to prevent prevailing winds from blowing directly into the outside air intake p...

Page 19: ...contact with any hot or sharp exterior surface areas of the stove Figure 11B Any stove installed in a mobile home must be electri cally grounded to the steel chassis of the home and bolted to the floor in Model compliance with and according to building code requirements 3 In Canada the electrical installation must meet the applicable requirements fo CSA C22 2 Figure 11B Insert Electrical Power Rou...

Page 20: ...for the area directly under the stove and extending 6 beyond the front of the stove as shown Models Prescott EX Figure s From Prescott EXL Afton Bay York 14 16B Sides of stove 1 14 16A B Back of stove rear face of control box 1 13 Corner of stove 1 13 Vent pipe 3 16 Stove to mantel 12 16 Floor protection Front from faceplate 6 12 Floor protection Sides back of stove 0 15 Alcove Vertical to Combust...

Page 21: ...ner of stove 1 13 Vent pipe 3 16 Stove to mantel 12 16 Floor protection Front from faceplate 4 12 Floor protection Sides back of stove 0 15 Alcove Vertical to Combustibles 16 17 Alcove Sides 1 17 Alcove Back 1 Models Prescott EX Figure 13 Top View Figure 14 Top View Clearances Corners of stove Clearances Sides and Back MINIMUM CLEARANCES INCHES TO COMBUSTIBLE MATERIAL 20 ...

Page 22: ...Alcove Installation Floorpad and Mantle clearances SideView Side View Figure 15 Figure 16 Alcove Installation Top View Figure 17 21 ...

Page 23: ...ly detailed requirements mobile home installations must observe the following Figure 17 1 WARNING DO NOT INSTALL IN A SLEEPING ROOM 2 WARNING COMBUSTION AIR MUST COME FROM THE OUTSIDE OF THE MOBILE HOME FAILURE TO DO SO MAY CREATE NEGATIVE PRESSURE WITHIN THE MOBILE HOME AND COULD DISRUPT PROPER VENTING AND OPERATION OF THE PELLET STOVE 3 CAUTION THE STRUCTURAL INTEGRITY OF THE FLOORS WALLS CEILIN...

Page 24: ...vent exits the structure 7 Check any other local building codes or other codes that may apply 8 Do no use components other than those specified for use with this unit Refer to pages 4 5 6 and 7 9 Floor protection requirement must be followed precisely 10 PL Vent must be used for exhaust venting Single wall vent is not allowed Follow PL Vent manufacturer s installation directions and observe all li...

Page 25: ...atpostion1 lowburn setting 1 Onceyouhavesuccessfullylityourstove setthethermostattoyourdesiredheatingneeds 2 Set the HEATADJUSTselector to a position which will effectively create a rise in room tem perature above your thermostat setting The recommended heat adjust settings while using a ther mostat are postion 2 through 6 NOTE Installers must determine a neutral location of where to mount the the...

Page 26: ...Notes Serial Number Date of Purchase Dealer Information 25 Even Temp Inc P O Box 127 Waco NE 68460 PHONE 402 728 5255 FAX 402 728 5379 EMAIL support eventempinc com WEB ADDRESS www eventempinc com ...

Page 27: ......