16
END OF SEASONAL CYCLE
TANK DRAINING
• The operator must:
a. Take the utmost care in carrying out the operations envisaged at the end of the daily treatments:
the cleaning of the main tank must be done at least twice. Check that no product residues are left
in any part the tank.
b. Execute the necessary maintenance and lubrication operations , then let the atomizer operate for
some minutes.
The pump must never run dry
c. Check the proper operation of all parts and of the machine structure. In case of faults being detected,
request the intervention of one of our service points.
d. Keep the machine on a plane surface with a suitable consistency, in a well ventilated place, sheltered
from rain, icing and direct sun rays.
The machine must be stored in a secure or closed place, so as to prevent access to
unauthorized personnel.
- Stop the tractor and remove the key from the control panel.
- Wear suitable protective clothing and accessories in order to avoid contamination
by contact or inhalation of the mixture.
- Carry out the discharging in a suitable and properly geared area for the collection
of the washing liquid.
Avoid using anti-freeze solutions.
A
EXECUTION:
1. Turn the tractor engine off.
2. Unscrew and remove the water drain plug (A).
3. Let the water from the inside of the tank flow out until totally
drained.
2. Screw back the water drain plug (A).
ST104-300LITER
- Mounted Sprayers