Getting started X-NUCLEO-S2868A1
17
DocIDxx
1
1
/
17
3.3
Current measurement
To monitor the power consumption of the entire S2-LP X-NUCLEO-S2915A1
board, jumper J1 can be used. Connect an ammeter probe between pins 1
and 2 of the connector for measurements.
3.4
X-NUCLEO-S2915A1 component placement details
Figure 3
shows the component placement on the S2-LP expansion X-
NUCLEO-S2915A1 board.
Figure 3. X-NUCLEO-S2915A1 component placement details