background image

4

Figure 1: Dimensions In Inches (mm)

Values given in tables below are for PUMP MOTOR ONLY. If additional
accessories are installed on pump motor circuit (heater, blower, etc.), in-

clude their amperage draw when figuring wire and circuit breaker sizes.

TABLE I - RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 HZ MOTORS

Branch 

Wire Gauge Size

Model

Motor

Voltage/

Full Load

Circuit Breaker

Dist. in Ft. (M)-Service Motor

Temp.

No.

H.P.

Hz/Phase

Amps

Rating (amps)

0-100’  (0-30)

101-200’ (31-60) 201-300’ (61-90)

Rating-°C

JWPD-075

3/4

115/60/1

9.2

15

14

12

10

75

JWPE-100

1

115/230/60/1

12.0/6.0

15

14/14

10/14

8/14

75

JWPF-150

1-1/2

115/230/60/1

16.0/8.0

20/15

12/14

8/14

6/12

75

Summary of Contents for JWPD-075

Page 1: ...WI 53185 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Orlando FL Union City TN Delavan WI Mississauga Ont 1995 Sta Rite Industrie...

Page 2: ...t its sole discretion Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty Requests for warranty service must be made through the installing dea...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Page 4: ...breaker sizes TABLE I RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 HZ MOTORS Branch Wire Gauge Size Model Motor Voltage Full Load Circuit Breaker Dist in Ft M Service Motor Temp No H P Hz P...

Page 5: ...e pipe dope pipe dope will cause stress cracking in the pump See Figure 4 NOTICE Pump suction and discharge connections have molded in thread stops DO NOT try to screw pipe in beyond these stops Tight...

Page 6: ...slope suction pipe slightly upward toward the pump See Figure 8 NOTICE To prevent flooding when removing pump for service all flooded suction systems must have gate valves in suction and discharge pi...

Page 7: ...onductor No 8 AWG 8 4 sq mm or larger Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool sp...

Page 8: ...y each time it is re moved Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTICE Tighten trap cover by hand only no wrenches Use a wrench o...

Page 9: ...Figure 12 Do not damage impeller surface where drive ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 13 re move seal plate and use a screwdriver to tap ceramic s...

Page 10: ...pump 1 Close all valves on suction and return piping 2 Remove drain plug in bottom of volute 3 Drain all piping exposed to freezing temperatures 4 Be sure no airlocks are holding water in the system...

Page 11: ...piping is too small 5 Check and clean pool filter 6 Consult dealer installer or service representative D CIRCUIT BREAKER IN HOME PANEL TRIPS REPEATEDLY 1 Breaker must be of adequate capacity 2 For GFC...

Page 12: ...1 C3 139P1 15 Trap Cover O Ring 1 U9 229 16 Trap Basket 1 C108 33P 17 Drain Plug 1 4 NPT 2 U178 920P 18 Capscrew 5 16 18x1 1 4 4 U30 64SS 19 Lock Washer 5 16 4 U43 11SS 20 Flat Washer 5 16 4 U43 41SS...