background image

5

Piping:

Use at least 1-1/2" IPS PVC pipe with 5” (127mm) trap. Use at least 2” pipe
with 6” (152mm) trap. Increase size if a long run is needed. 
To avoid strains on the pump, support both suction and discharge pipes inde-
pendently. Place these supports near the pump.
To avoid a strain left by a gap at the last connection, start all piping at the
pump and run pipe away from the pump.
Never use a suction pipe smaller than pump suction connection. To avoid air-
locking, slope suction pipe slightly upward toward the pump.
NOTICE: To prevent flooding when removing pump for service, all flooded
suction systems must have gate valves in suction and discharge pipes.

Fittings:

Fittings restrict flow; for best efficiency use fewest possible fittings.
Avoid fittings which could cause an air trap.
Pool fittings must conform to International Association of Plumbing and
Mechanical Officials (IAPMO) standards.
Use only non-entrapping suction fitting or double suction.

TABLE I - RECOMMENDED FUSING AND WIRING DATA

Serv. to Motor - Dist. in Ft. (M)

Motor

Branch Fuse

Max Load

Voltage/

0-100'

101-200'

201-300'

HP

Rating Amps*

Amps

Hz/Phase

(0-30M)

(30-60M)

(60-90M)

1/2

15

11.0

115/60/1

14(2)

10(5.5)

8(8.4)

3/4

20

13.8

115/60/1

12(3)

10(5.5)

8(8.4)

1

25

16.0

115/60/1

12(3)

8(8.4)

6(15.5)

1/2

15

5.5

230/60/1

14(2)

14(2)

14(2)

3/4

15

6.9

230/60/1

14(2)

14(2)

14(2)

1

15

8.0

230/60/1

14(2)

14(2)

14(2)

1-1/2

15

10.4

230/60/1

14(2)

14(2)

12(3)

2

15

11.2

230/60/1

14(2)

14(2)

12(3)

3

25

15.8

230/60/1

12(3)

12(3)

10(5.5)

3

15

9.7

230/60/3

14(2)

14(2)

12(3)

3

15

4.9

460/60/3

14(2)

14(2)

14(2)

1/2

15

12.0

100/60/1

14(2)

10(5.5)

8(8.4)

3/4

20

13.4

100/60/1

14(2)

12(3)

8(8.4)

1/2

15

6.0

200/60/1

14(2)

14(2)

14(2)

3/4

15

6.7

200/60/1

14(2)

14(2)

14(2)

1

15

8.5

200/60/1

14(2)

14(2)

12(3)

1-1/2

15

10.5

200/60/1

14(2)

12(3)

12(3)

2

20

14.2

200/60/1

12(3)

12(3)

10(5.5)

3

25

17.6

200/60/1

10(5.5)

10(5.5)

10(5.5)

* Time delay fuses are recommended instead of standard fuses in any motor circuit.

AWG

Wire

Size

(mm

2

)

}

Summary of Contents for MAX-E-GLAS PE Series

Page 1: ...2G 122 3 PE6H 139L PE62H 139 3 PE6H 139LC PE6H3 139 Sta Rite Pool Spa Group 600 S Jefferson Street Waterford WI 53185 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728...

Page 2: ...he Sta Rite PE Series Self priming Centrifugal pump Is designed for use with swimming pools or as a centrifugal pump Is an excellent performer durable reliable Table of Contents Safety Instructions 3...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Page 4: ...CE Use Teflon tape or Plasto Joint Stik1 for making all threaded connections to the pump Do not use pipe dope pipe dope will cause stress cracking in the pump NOTICE Pump suction and discharge connect...

Page 5: ...ical Officials IAPMO standards Use only non entrapping suction fitting or double suction TABLE I RECOMMENDED FUSING AND WIRING DATA Serv to Motor Dist in Ft M Motor Branch Fuse Max Load Voltage 0 100...

Page 6: ...mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or con...

Page 7: ...Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTICE Tighten trap cover by hand only no wrenches Use a wrench only if necessary to remove...

Page 8: ...tem Propylene glycol is non toxic and will not damage plastic system components other anti freezes are highly toxic and may also damage plastic components in the system Drain all water from pump and p...

Page 9: ...e 3 Remove clamp holding pump halves together 4 Remove pump base mounting bolts if used Motor and seal plate assem bly can now be pulled away from pump body 5 Remove five screws and washers holding di...

Page 10: ...unterclockwise 8 Mount diffuser on seal plate tighten screws to 10 14 inch lbs 11 5 16 1 cent kg torque 9 Assemble motor and seal plate to volute be sure clamp is properly seated NOTICE Clamp knob can...

Page 11: ...er 7 Make sure impeller is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 10 for reassembly 8...

Page 12: ...Clamp Knob 1 WC36 22 10 Impeller 1 Chart at Right 11 Diffuser 1 C1 200PA 12 Screw 8 32x7 8 5 U30 542SS 13 Washer 8 Lock 5 U43 21SS 14 Diffuser O Ring 1 U9 226 15 Tank Body 1 C176 47P1 16 1 4 NPT Drai...

Page 13: ...w 8 32x7 8 5 U30 542SS 13 Washer 8 Lock 5 U43 21SS 14 Diffuser O Ring 1 U9 226 15 Tank Body 1 C176 47P1 16 1 4 NPT Drain Plug 1 U178 920P 17 Base w Motor Pad 1 C104 42P 18 Motor Pad 1 C35 11 19 Washer...

Page 14: ...C30 12 11 Diffuser 1 C1 259P 12 Screw 8 32x7 8 5 U30 542SS 13 Washer 8 Lock 5 U43 21SS 14 Diffuser O Ring 1 U9 226 15 Tank Body 1 C176 47P1 16 1 4 NPT Drain Plug 1 U178 920P 17 Base w Motor Pad 1 C104...

Page 15: ...Capscrew 5 16 18x1 1 4 U30 64SS 4 U30 64SS 4 8 Washer Lock 5 16 U43 11SS 4 U43 11SS 4 9 Washer Flat 5 16 U43 41SS 4 U43 41SS 4 Quantity one unless otherwise indicated Overhaul Kits H P Parts Pak Numbe...

Page 16: ...ence misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Reviews: