background image

3

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. 

When you see this

symbol in this manual, look for one of the follow-

ing signal words and be alert to the potential for personal

injury.

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if

ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if

ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The label 

NOTICE 

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this

manual and on equipment.

End user should save these instructions.

GENERAL SAFETY!

Hazardous voltage.

Incorrectly installed or

tested equipment may fail, causing severe injury or prop-

erty damage. Read and follow instructions in owner's

manual when installing and operating equipment.

Installation and maintenance of this circuit, the light, light

niche, and any other accessories attached to the circuit,

must be performed by a licensed electrician.

The complete electrical system must be installed, tested,

and approved by a licensed electrician before it is placed

in operation. Failure to have this product installed by a

licensed professional will void the product warranty.

Risk of electrical shock.

Before removing

fixture from pool wall, ALWAYS TURN OFF THE POWER

at the breaker.

All 12 Volt lamps require the installation of a 12 Volt

transformer.

This light and its light niche must be installed in accor-

dance with Article 680 of the National Electrical Code

(NEC), in the United States, or Section 68 of the Canadian

Electrical Code (CEC), as applicable, and all local code

requirements.

Install an approved Ground Fault Circuit Interrupter in

the electrical circuit for this light.

All devices in the system must be directly grounded to a

positive electrical ground. All devices in the system must

meet all applicable code requirements for bonding.

Burn hazard.

Never operate this light fix-

ture for more than 10 seconds unless it is completely

submerged in water. This fixture requires total submer-

sion for cooling.

Breakage hazard.

Install fixture in a vertical

pool or spa wall – not in floor. Failure to install the fix-

ture properly could result in personal injury and/or prop-

erty damage. Do not push off from the poolside against

the light.

Except when the fixture is installed in an area of the

swimming pool that is not used for swimming and the

lens is adequately guarded to keep any person from con-

tacting it, the fixture shall be installed in or on a wall of

the pool, with the top of the lens opening not less than

18" below the normal level of the pool.

Locate junction box at least 8" above maximum water

level and not less than 4 feet from the perimeter of the

pool. 

The junction box must be located:

at least 4’ from the perimeter of the pool (unless sepa-

rated from the pool by a solid fence, wall or other

permanent structure,

at least 8" above maximum water level,

at least 4" above the deck or ground level.

Make sure that the installation is in compliance with

local codes, the NEC, and the CEC, as applicable. See

Figure 1, Page 5.

The improper use of Ozone generators, Chlorine genera-

tors, Copper/Silver Ion generators or certain chemicals

for water purification may cause damage to the fixture.

When such water purification methods are used, be sure

to monitor the water conditions. Subjecting the fixture to

extreme conditions or harsh environments may cause

corrosion and premature failure of the fixture or its 

components.

Cutting hazard if light is improperly

installed.

This light is for use only in commercial and

residential swimming pools and spas. It has not been

designed, tested, or approved for use in wave pools,

lazy rivers, or other waterpark features, and should not

be used in them. Use in any application other than a

swimming pool or spa may lead to damage to the light

and cuts to swimmers and will void the warranty. 

Sta-Rite will not be responsible for any damages or

injuries due to misapplication of this light.

Summary of Contents for Small Underwater Pool Lights SunLite LTC

Page 1: ...330 800 831 7133 or 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 800 831 7133 or 805 553 5000 Visit us on the Internet at www pentairpool com or www staritepool com S715 Rev A 10 29 07 This manual should be furnished to the end user of this light its use will reduce service calls and chance of injury and will lengthen light life 3051 0997 ASB ...

Page 2: ...ght installations must conform with all codes Under no circumstances replace lights by splicing wire under water or behind niche WARNING RISK OF ELECTRIC SHOCK AND INJURY USE ONLY THE INSTALLATION METHOD SPECIFIED BELOW Important Safety Information for Fountain Fixture Installations Location of Pentair Fountain Fixture Required Installation Method Luminaire Use P N 560000 P N 560001 P N 560002 P N...

Page 3: ...tem must meet all applicable code requirements for bonding Burn hazard Never operate this light fix ture for more than 10 seconds unless it is completely submerged in water This fixture requires total submer sion for cooling Breakage hazard Install fixture in a vertical pool or spa wall not in floor Failure to install the fix ture properly could result in personal injury and or prop erty damage Do...

Page 4: ...ll lighted 2 Never install lights in end walls at end of swimming lanes However if short course racing is provided across width of a 50 meter course light fixtures may be installed between lanes under racing lines on a seperate switch Table I SPECIFICATIONS Model No Cord Length in Feet m 12V 75 Watts 05603 2030 30 9 1 05603 2050 50 15 2 05603 2100 100 30 5 120V 100 Watts 05605 2030 30 9 1 05605 20...

Page 5: ...t fixture Connect the line supply wire the black or hot wire to the black wire from the light fixture Connect the neutral white supply wire to the neutral white wire from the light fixture 4 Coil the remaining cord in the back of the niche and place the lamp housing in the niche The mounting tab on the bottom of the lamp housing must be in the notch at the bottom of the niche 5 Fasten the lamp hou...

Page 6: ...e fingers If contact occurs clean the lamp glass with alcohol and a clean cloth 6 To close the fixture make sure the clamp ring is open to about 4 inches and that the nut is at the end of the leader screw 7 Lay the face ring face down on a flat surface Carefully align the clear lens Key No 4 and lens gasket Key No 5 over the flanged hole in the face ring key No 2 with the word top on the lens line...

Page 7: ...1 0014 05601 0014 05601 0014 6 Clamp Ring Assembly 1 05601 0006 05601 0006 05601 0006 7 Lamp Housing 1 Lamp 100W 120V Halogen T 4 MC 1 79102900 Lamp 75W 12V Halogen MR 16 1 79112400 Lamp 250W 130V Halogen T 4 MC 1 79113800 Replacement Screw Kit 1 05601 0101 05601 0101 05601 0101 REPAIR PARTS LIST SUNLITE LTC LAMPS Not sold separately Not illustrated Included with Replacement Screw Kit 1 2 3 5 6 7 ...

Page 8: ...pa Inc All rights reserved 1620 HawkinsAve Sanford NC 27330 800 831 7133 or 919 566 8000 10951 W Los Angeles Ave Moorpark CA 93021 800 831 7133 or 805 553 5000 This document is subject to change without notice 8 S715 Rev A 10 29 07 ...