Lamp Installation Instructions (Re-lamping)

See Figure 2, Page 7, for Key numbers.

1. Be sure that the power is off. Allow the lamp to cool

before relamping.

2. Remove the leader screw (Key No. 1) from the face

ring and lift the lamp housing up and out of the

niche.

3. Loosen the screw and nut on the clamp ring assembly

(Key No. 5) until the nut is near the end of the screw.

Swing the screw and nut out of the forked slot of the

clamp ring assembly and bend the clamp ring open

to about 4 inches.

4. To relamp 120V model, remove the lamp by turning

it counterclockwise and pulling it straight out.

Replace with an equivalent lamp. For the 12V model,

remove the lamp by pulling it straight out while hold-

ing the spring clip back (away from the socket).

Replace with an equivalent lamp.

5. Using a clean soft lint free cloth, carefully wipe all

sealing surfaces on the lamp housing and lens.

NOTE: 

Do not touch the lamp with your bare fingers.  If

contact occurs, clean the lamp glass with alcohol and a

clean cloth.

6. To close the fixture, make sure the clamp ring is open

to about 4 inches and that the nut is at the end of the

leader screw.

7. Lay the face ring face down on a flat surface.

Carefully align the clear lens (Key No. 4) and lens

gasket (Key No. 5) over the flanged hole in the face

ring (key No. 2), with the word “top” on the lens

lined up with the leader screw on the face ring. The

silver tape should be on top and the arrow pointing

toward the lamp.

8. Align the lamp housing over the lens gasket with the

word “top” inline with the leader screw in the face

ring.  

9. Position one half of the clamp ring around the metal

flanges of the face ring and lamp housing.

10. Close the clamp ring, fitting the other half over the

same flanges.

11. Swing the nut and screw into the slotted end of the

clamp assembly. Tighten this screw securely (20 inch-

pounds torque) to insure good electrical bonding.

12. To replace the lamp housing in the pool wall hook

the bracket at the bottom of the niche and tighten the

leader screw on the face ring of the lamp housing. 

6

Summary of Contents for Small Underwater Pool Lights SunLite LTC

Page 1: ...330 800 831 7133 or 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 800 831 7133 or 805 553 5000 Visit us on the Internet at www pentairpool com or www staritepool com S715 Rev A 10 29 07 This manual should be furnished to the end user of this light its use will reduce service calls and chance of injury and will lengthen light life 3051 0997 ASB ...

Page 2: ...ght installations must conform with all codes Under no circumstances replace lights by splicing wire under water or behind niche WARNING RISK OF ELECTRIC SHOCK AND INJURY USE ONLY THE INSTALLATION METHOD SPECIFIED BELOW Important Safety Information for Fountain Fixture Installations Location of Pentair Fountain Fixture Required Installation Method Luminaire Use P N 560000 P N 560001 P N 560002 P N...

Page 3: ...tem must meet all applicable code requirements for bonding Burn hazard Never operate this light fix ture for more than 10 seconds unless it is completely submerged in water This fixture requires total submer sion for cooling Breakage hazard Install fixture in a vertical pool or spa wall not in floor Failure to install the fix ture properly could result in personal injury and or prop erty damage Do...

Page 4: ...ll lighted 2 Never install lights in end walls at end of swimming lanes However if short course racing is provided across width of a 50 meter course light fixtures may be installed between lanes under racing lines on a seperate switch Table I SPECIFICATIONS Model No Cord Length in Feet m 12V 75 Watts 05603 2030 30 9 1 05603 2050 50 15 2 05603 2100 100 30 5 120V 100 Watts 05605 2030 30 9 1 05605 20...

Page 5: ...t fixture Connect the line supply wire the black or hot wire to the black wire from the light fixture Connect the neutral white supply wire to the neutral white wire from the light fixture 4 Coil the remaining cord in the back of the niche and place the lamp housing in the niche The mounting tab on the bottom of the lamp housing must be in the notch at the bottom of the niche 5 Fasten the lamp hou...

Page 6: ...e fingers If contact occurs clean the lamp glass with alcohol and a clean cloth 6 To close the fixture make sure the clamp ring is open to about 4 inches and that the nut is at the end of the leader screw 7 Lay the face ring face down on a flat surface Carefully align the clear lens Key No 4 and lens gasket Key No 5 over the flanged hole in the face ring key No 2 with the word top on the lens line...

Page 7: ...1 0014 05601 0014 05601 0014 6 Clamp Ring Assembly 1 05601 0006 05601 0006 05601 0006 7 Lamp Housing 1 Lamp 100W 120V Halogen T 4 MC 1 79102900 Lamp 75W 12V Halogen MR 16 1 79112400 Lamp 250W 130V Halogen T 4 MC 1 79113800 Replacement Screw Kit 1 05601 0101 05601 0101 05601 0101 REPAIR PARTS LIST SUNLITE LTC LAMPS Not sold separately Not illustrated Included with Replacement Screw Kit 1 2 3 5 6 7 ...

Page 8: ...pa Inc All rights reserved 1620 HawkinsAve Sanford NC 27330 800 831 7133 or 919 566 8000 10951 W Los Angeles Ave Moorpark CA 93021 800 831 7133 or 805 553 5000 This document is subject to change without notice 8 S715 Rev A 10 29 07 ...