196 / 196 M electronic IP65

4

en

After switching on, an automatic self-test is carried out. 

All the display's segments are shown.  

 

After the end of the test, the version number S x.xx of the 

measurement program is briefly displayed and the saved 

automatic switch-off time of 1/8 or 2 hours displayed.  

 

 

 

An acoustic signal indicates that the unit is ready for 

operation. 

The display shows the angle measured in the set unit  

of measurement.

Commissioning

test

off

Software Version

Summary of Contents for 196 electronic IP65

Page 1: ...Operating Instructions 196 electronic IP65 196 M electronic IP65 EN ...

Page 2: ... still have any questions after reading the operating instructions feel free to call our hotline 0049 63 46 3 09 0 Equipment and functions vertical vial s for vertical levelling in reverse position too horizontal vial for horizontal levelling in reverse position too electronic module with 2 digital displays for accurately determining inclinations and angles Operating Instructions ...

Page 3: ...asurement memory Lighting Acoustic signal Calibration Button lock 1 2 Displays 2 Battery compartment lid 3 Magnet 196 M electronic IP65 4 Vials vertical and horizontal 5 Removable shock absorbing end caps 6 Anti slip stopper 7 Electronic module dust proof and waterproof in accordance with IP 65 IP 65 IP 65 ...

Page 4: ...ing to symbol in battery compartment Suitable rechargeable batteries can also be used LCD low battery charge insert new battery Dispose of used batteries at suitable collection points not with household waste Do not leave in unit Remove the batteries if you do not intend to use the unit for some time Insert batteries Battery replacement ...

Page 5: ...he end of the test the version number S x xx of the measurement program is briefly displayed and the saved automatic switch off time of 1 8 or 2 hours displayed An acoustic signal indicates that the unit is ready for operation The display shows the angle measured in the set unit of measurement Commissioning test off Software Version ...

Page 6: ...e is activated deactivated using the Acoustic signal button If the acoustic signal is activated the tone sequence speeds up as the 0 or 90 position is approached in a range of 2 to the horizontal or vertical A change in the pitch indicates that these positions have been exceeded A continuous tone confirms the precise point at which the horizontal vertical is reached This is also indicated on the d...

Page 7: ...ral times Rough Display in 0 1 steps Fine Display in 0 05 steps Display in 0 1 steps mm m Display in 1 mm m steps in ft decimal Display in 0 01 in ft steps in ft fraction Display in 1 8 in ft steps The set unit of measurement is retained after the unit is switched off Setting the unit of measurement MODE ...

Page 8: ...g the REF button The reference angle is deleted by Pressing and holding 3 sec the REF button If the button lock is active this must be disabled first Switching off The automatic switch off function The zero position again refers to the calibrated setting The alignment selected for the electronic spirit level must not be changed during the reference function Reference angle freely selectable zero p...

Page 9: ...is button is confirmed by an acoustic signal Lighting 1x 1x 1x on 60 sec on Button lock Pressing and holding 3 sec the Key button locks the Operating mode selection Reference Measurement memory Calibration buttons The button lock remains active after switching the unit off and back on again Pressing and holding the Key button disables the button lock The pressing of this button is confirmed by an ...

Page 10: ...ment can be saved by pressing the HOLD button The arrows and the centre display bars flash The measurement is displayed continuously Close to 0 and 90 the arrows flash to indicate direction The saved measurement is deleted by again pressing the HOLD button or switching the unit off ...

Page 11: ...stic signal buttons at the same time allows the automatic switch off time to be changed from 1 8 hours approx 7 5 minutes to 2 hours The set switch off time is retained after the unit is switched off and is displayed briefly when it is switched on again 8 1 h 7 5 min 2h 2 1 1x 1x Acoustic signal The acoustic alignment guide is activated deactivated using the Acoustic signal button ...

Page 12: ...he measuring surfaces of the electronic spirit level should be positioned precisely for all measurement work If positioned at too great an angle the tilt function prevents incorrect measurements The display doesn t then show any measurements 5 5 5 5 ...

Page 13: ...acy must always be checked 1 Switch on the electronic spirit level Use the vial to accurately align the unit to a wall for example until the vial bubble is in the middle between the vial rings 2 Wait 10 seconds If the value displayed is 0 05 the electronic spirit level must be recalibrated If mainly used for vertical measurements the accuracy check can also be undertaken with the vertical vial 10 ...

Page 14: ...rtical vial 2 Hold the electronic spirit level in this position and press the CAL button The CAL display shows calibration mode 3 Calibration starts when the CAL button is pressed again CALIBRATE 1x 1x 1x Newly calibrated value with deviation of 1 from factory setting Recalibrate spirit level Vibration during calibration Recalibrate spirit level Calibration completed successfully Spirit level read...

Page 15: ...bration The electronic spirit level is calibrated in 4 measuring positions consecutively turning 90 180 each time Calibration in 4 positions Step 1 Press CAL and MODE buttons at the same time Align the electronic spirit level accurately against a wall and press the CAL button to confirm Only the 1st calibration step is performed with the vial 1x Flashing segments indicate the positions still to be...

Page 16: ...rows displayed The electronic spirit level is aligned horizontally using the arrows displayed The 2 centre display bars indicate the precise position at which the horizontal is reached Confirm with the CAL button Flashing segments indicate the positions still to be calibrated Non flashing segments indicate the positions already calibrated ...

Page 17: ...urned 90 and aligned vertically using the arrows displayed The 2 centre display bars indicate the precise position at which the vertical is reached Confirm with the CAL button The flashing segment indicates the position still to be calibrated Non flashing segments indicate the positions already calibrated ...

Page 18: ...4 The electronic spirit level is turned 180 and aligned vertically using the arrows displayed The 2 centre display bars indicate the precise position at which the vertical is reached Confirm with the CAL button rdy display Calibration in 4 positions successfully completed ...

Page 19: ...ng defects for a period of 24 months from the date of purchase Any defects errors will be remedied at our discretion through reworking or replacement STABILA will not assume liability for further claims Defects resulting from improper handling e g damage due to application of serious force operation with incorrect voltage current type use of unsuitable power source and unauthorised modifications t...

Page 20: ... P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 76855 Annweiler Tel 49 63 46 309 0 Fax 49 63 46 309 480 E mail info stabila de www stabila de STABILA Inc 332 Industrial Drive South Elgin IL 60177 1 800 869 7460 www stabila com USA Canada ...