background image

15

Replacing the batteries

Slide the battery cover (4) in the direction of
the arrow and insert new batteries in 
accordance with the symbols in the battery
compartment.

4 x 1,5V
alkaline mignoncells,  
size AA, LR6

Tip:

Remove the batteries if the unit will not be used for a long period !

Recycling programme for our EU customers:

In accordance with the WEEE regulations, STABILA provides a disposal
programme for electronic products at the end of their service life.
For more details, please contact: 
www.STABILA.de / Recycling 
or: 
0049 / 6346 / 309-0

NB:

In Class II laser equipment, your eyes
are protected from accidental, short-
term exposure to the laser beam by
the lid-closing reflex and/or the reflex
reaction to turn one's head. This
equipment can therefore be used
without additional protective measu-
res. Nevertheless, you should not look
directly into the laser beam. 

The laser goggles enclosed with these
units are not safety goggles. They are desi-
gned to make the laser light easier to see.

Do not let the unit fall into children's
hands!

EN 60825-1 : 03 10

Summary of Contents for LA-4P

Page 1: ...Laser LA 4P Operating instructions GB...

Page 2: ...A 2 4 7 6 12 11 1 8 10 14b 9 3a 3a 3c 3b 5 14a 14c 11...

Page 3: ...F C B E D G 50mm 115 mm 1 2 2 4 5...

Page 4: ...I K L M s 6m N Q O P1 P2 20ft 13...

Page 5: ...ical levelling and plumb lines This simple to use tool allows you to transfer points between the floor and ceiling and to establish 90 points for laying out wall lines and putting up wall partitions Y...

Page 6: ...ot is marked Place the laser on a flat surface The laser must be within 4 of being level for it to self level Holding down the ON OFF key for 3 seconds activates automatic switch off after 60 minutes...

Page 7: ...0 and realign the down beam over the reference mark on the floor 4 Place the laser so that its down beam is over a reference mark on the floor Switch the unit on button 1 1 The LA 4P four point laser...

Page 8: ...eight of the laser Two parallel wall surfaces at least 6m or 20 ft apart are required for the horizontal check 1 Without changing the height of the laser rotate it 180 to place the beam near the mark...

Page 9: ...that the level beam aligns with point D 7 Mark the location of the square beam E on the floor as close as possible to point A 8 Measure the distance between points A and E 9 5 Move the LA 4P to point...

Page 10: ...ts at the end of their service life For more details please contact www STABILA de Recycling or 0049 6346 309 0 NB In Class II laser equipment your eyes are protected from accidental short term exposu...

Page 11: ...voltage very low battery replacement required imminently Laser beam f fl la as sh hi in ng g The unit is inclined too much is outside the self levelling range the laser cannot level itself automatica...

Page 12: ...ntee are accepted for natural wear and tear or any small faults that do not significantly affect the unit s operation Any guarantee claims must be made via the dealer on the duly completed guarantee f...