background image

11

Getting started

Please note that if the laser beams are to travel through glass or other transparent
materials, this can adversely affect the laser's accuracy

Press the power button. The green power-status LED lights to show that the laser
is on.

Setting Up the Laser and Transferring a Point

Locate the position of the up beam and level beam.
Make a mark on the ceiling and wall respectively.

Adjust the position of the laser so that the down beam is on
the control point.

Place the laser so that the bottom feet are on the front edge of the bottom
track.

Plumbing a Wall

Please note that the centre of laser dot is marked!

Place the laser on a flat surface. The laser must be within ±4° of being level for it to
self-level.

Holding down the ON / OFF key for 3 seconds activates automatic switch-off
after 60 minutes.

1.

3.

2.

Tip:

Place the adapter with the centring feet in the drill hole.

The drill hole point can now be perpendicularly transferred quite easily.

Slide the lock in the direction of the arrow. The centring feet now centre
the adapter precisely in the drill hole. 

1.

3.

2.

With the adapter, you can easily perpendicularly transfer the centre points
for drill holes with diameters of 50mm (1,96”) to 115 mm ( 4,72”).

Transferring drill hole points :

E

D

F

G

1

1

Adjust the top of the partition until the up beam is on the front edge of
the top track.

Switch the unit on ( button 1)

Illuminated g

grre

ee

en

n LED

-> laser in operation

C

Summary of Contents for LA-4P

Page 1: ...Laser LA 4P Operating instructions GB...

Page 2: ...A 2 4 7 6 12 11 1 8 10 14b 9 3a 3a 3c 3b 5 14a 14c 11...

Page 3: ...F C B E D G 50mm 115 mm 1 2 2 4 5...

Page 4: ...I K L M s 6m N Q O P1 P2 20ft 13...

Page 5: ...ical levelling and plumb lines This simple to use tool allows you to transfer points between the floor and ceiling and to establish 90 points for laying out wall lines and putting up wall partitions Y...

Page 6: ...ot is marked Place the laser on a flat surface The laser must be within 4 of being level for it to self level Holding down the ON OFF key for 3 seconds activates automatic switch off after 60 minutes...

Page 7: ...0 and realign the down beam over the reference mark on the floor 4 Place the laser so that its down beam is over a reference mark on the floor Switch the unit on button 1 1 The LA 4P four point laser...

Page 8: ...eight of the laser Two parallel wall surfaces at least 6m or 20 ft apart are required for the horizontal check 1 Without changing the height of the laser rotate it 180 to place the beam near the mark...

Page 9: ...that the level beam aligns with point D 7 Mark the location of the square beam E on the floor as close as possible to point A 8 Measure the distance between points A and E 9 5 Move the LA 4P to point...

Page 10: ...ts at the end of their service life For more details please contact www STABILA de Recycling or 0049 6346 309 0 NB In Class II laser equipment your eyes are protected from accidental short term exposu...

Page 11: ...voltage very low battery replacement required imminently Laser beam f fl la as sh hi in ng g The unit is inclined too much is outside the self levelling range the laser cannot level itself automatica...

Page 12: ...ntee are accepted for natural wear and tear or any small faults that do not significantly affect the unit s operation Any guarantee claims must be made via the dealer on the duly completed guarantee f...