ACE Stoßdämpfer GmbH · Postfach 1510 · D-40740 Langenfeld · T +49 (0)2173 - 9226-10 (Technik -20) · F +49 (0)2173 - 9226-19 · info@ace-int.eu · www.ace-ace.com
Stand 03.2021
ACE Stoßdämpfer GmbH · www.ace-ace.com
21_22_0019 Issue 05.2022
2
α
WARNING
If ACE rotary dampers are used where a failure of the
product could lead to personal injuries and/or material
damage, additional safety elements must be implemented.
Free-moving masses, such as lids, flaps, covers etc., can
lead to injuries by crushing during installation of the rotary
dampers.
Secure moving flap/mass against falling down!
Intended use
ACE rotary dampers ensure the controlled opening and closing of
small covers, compartments and drawers. They can brake directly
at the pivot point or linearly via rack and pinion to attain a smooth
and quiet movement. Sensitive components are preserved. The
harmoniously gentle process increases the quality and value of
the product.
Description and function
On the adjustable rotary dampers with a partial rotation angle
the fluid is pressed from one chamber to another by the rotor
movement. The damping torque is determined by the viscosity of
the fluid or the dimensioning of the damping orifice or metering
orifice. During each reverse movement of the unilateral decelerat-
ing versions there is a certain return damping torque that depends
on the size.
ACE rotary dampers are maintenance-free and ready-to-install.
The damping direction can be rotating right/left or two-sided. The
outer bodies are made from zinc die-cast. The dampers can be
mounted directly at the pivot point.
Safety information
Delivery and storage
- After delivery please check the rotary dampers for any damage.
- The rotary damper can become damaged if it falls. Carefully
remove rotary damper from the packaging.
- Rotary dampers can generally be stored in any position.
- Storage in the original packaging is preferred.
- Always store rotary dampers dry.
- The recommended maximum storage time is two years.
- Storage of rotary dampers is permissible at -20 °C to +70 °C.
Maintenance and care
Regularly check the rotary damper for oil loss and external dam-
age. Rotary dampers are machine elements that are subject to
continuous wear. Increased service life results in reduced braking
effect. If this is no longer sufficient, the rotary dampers must be
replaced or exchanged as appropriate.
Disassembly and disposal
Take account of environmental protection (recovery of problematic
substances) during disposal of the rotary dampers. The rotary
dampers are filled with silicone oil. The corresponding data sheet
is available on request. By design, the silicone oil cannot be
refilled. The rotary dampers cannot be repaired. Faulty brakes can
be sent to our service department for determination of the cause
of failure.
Calculation steps
1. Calculate torque for unfavourable angle
(see example on left: 0°).
2. Determine angular speed.
3. Choose a suitable rotary damper for the calculated torque.
4. With the aid of the damper performance curve, check whether
the rpm matches the desired speed.
5. If the rpm is too high – choose a higher torque.
6. If the rpm is too low – choose a lower torque.
Torque
M = L / 2 · m · g · cos α
(L / 2 = centre of gravity)
m
Mass in kg [1 kg = 9.81 N]
L
Flap length in cm
n
Speed in rpm
Calculation example: Damping of a flap
In order to select a suitable rotary damper for the calculation
example shown, the length and the weight or centre of gravity of
the flap must be specified. Once the max. torque value with an
unfavourable angle of the flap has been determined, a suitable
brake is selected.
General instructions
This manual is for the disruption-free use of the product
types listed on page 1; its compliance is a prerequisite
for the fulfilment of any warranty claims.
Therefore, make sure to read this manual before use.
Always maintain the limits specified in the performance
table. Take into account the predominant environmental
conditions and restrictions. Note the regulations of
the trade association, TÜV or corresponding national,
international and European regulations. Installation and
commissioning only according to mounting instructions.
Calculation and design
In order to ensure an optimum fault-free and durable function of the rotary dampers, they must be correctly dimensioned and designed. The following parameters
must be known and used in the calculation.
- Temperature
- Damping torque
- Speed
- Cycle number
Should you have any further questions about the use of rotary dampers, please contact one of our ACE technicians.
For free calculation service, phone: +49 (0)2173 - 9226-20.
Rotary Damper FYT-LA3 and FYN-LA3 (partial rotation angle, adjustable)
Manual