Page
ST315
User
Handbook
8
Note: to exit programming without cycling through all of the above steps wait 10
seconds without pressing any keys—the ST315 will revert to the idle display.
Alternatively press the START/STOP key to exit programming and to begin firing
immediately.
Pr
ogramming
End
°C
°C/hr
hr.min
Data entry is terminated if
End
is selected for a
ramp rate with the
ª
key. Data entry is also
automatically terminated if 9 segments have been
entered.
Note: the
§
key can be used to reverse through the programming steps to correct
errors or to exit programming mode.
Note: available ramp rate displays are:
End
,
1
…
999
&
FULL
.
If
End
is
shown but another segment is required then push the
©
key to obtain the
required ramp rate (in the range 1°C/hr to 999°C/hr). If full power is required
then push the
©
key until
FULL
is diplayed.
ST315 User Handbook
Page 13
Cooling
Upon completion of firing the ST315 lights all lamps on the mimic dis-
play and the kiln is allowed to cool naturally.
120
°C
°C/hr
hr.min
Hot
°C
°C/hr
hr.min
39
°C
°C/hr
hr.min
End
°C
°C/hr
hr.min
While the kiln temperature is above 40°C the display alternates every 5
seconds between the kiln temperature and
Hot
When the kiln has cooled to less than 40°C the display alternates every 5
seconds between the kiln temperature and
End
To return the ST315 back to idle condition ready for the next firing press
the START/STOP key (or turn off the power to the instrument).
Cooling