background image

Thank you for purchasing the Stahl Tools Digital Soldering Test Station. Its desktop design combines a multimeter, power 
supply, and variable temperature soldering iron all-in-one unit. This enables you to create or repair, power, and test your work 
saving time, space, and money compared to having three separate units.

Callouts

Power Specifications

Multimeter 

1.

  Display

2.

  Back light

3.

  Hold function

4.

  Selector knob

5.

  Positive 10A socket for red probe  

(for high amperage testing only)

6.

  Positive socket for red probe (for most testing 

applications except high amperage)

7.

  Negative socket for black probe

Power Supply

8.

  Coarse adjustment voltage control

9.

  Negative wire jack

10.

  Ground jack (if needed)

11.

  Positive jack

12.

  Fine adjustment voltage control

13.

  On/off button

14.

  Display

Soldering Station

15.

  Soldering iron 5-pin socket

16.

  Temperature adjustment/power knob

17.

  Desired temperature display

18. 

Current temperature display

Back of unit

19.

  Power socket/fuse holder

20.

  Main power switch

21.

  9 volt battery compartment for multimeter

22.

  Compartment for connecting cables and test leads

Input:

 100~240 VAC, 50/60 Hz

Soldering Station:

 24V 40W

Digital-Multimeter:

 9V BATTERY (6F22)

Power Supply:

 1.2~12 VDC, 1A 15W (MAX)

3

Summary of Contents for DSTS

Page 1: ...Model DSTS User Manual Variable Temperature Digital Solder and Testing Station...

Page 2: ...ll reach as high as 400 C 752 F do not touch metallic parts near the soldering tip when the power switch is on 7 A fire may result if the appliance is not used with care therefore do not leave the app...

Page 3: ...d probe for most testing applications except high amperage 7 Negative socket for black probe Power Supply 8 Coarse adjustment voltage control 9 Negative wire jack 10 Ground jack if needed 11 Positive...

Page 4: ...y elements will be switched on briefly The electronic system will automatically turn on to the set temperature and display the current value Display and temperature setting 1 Display for actual temper...

Page 5: ...er or electrical specifications before using the meter 3 Do not apply more than the rated voltage as marked on the multimeter between the terminals or between any terminal and grounding 4 The rotary s...

Page 6: ...play 2 Display backlight button 3 HOLD button 4 Function selector knob 5 Positive 10A socket for red probe for high amperage testing only 6 Positive socket for red probe for most testing applications...

Page 7: ...000m 10 Battery Type One 9V Battery NEDA 1604 6F22 or 006P 11 Battery Deficiency Display 12 Negative reading Display 13 Overload Display 1 14 Accuracy a reading b digits see charts below guarantee for...

Page 8: ...voltage measurement has been completed disconnect the connection between the testing leads and the circuit under test AC Voltage Measurement see figure 2 Warning To avoid injury to you or damage to th...

Page 9: ...ined 2 When current measurement has been completed disconnect the connection between the testing leads and the circuit under test Measuring Resistance see Figure 4 Warning To avoid damage to the multi...

Page 10: ...t test General Service 1 Periodically wipe the case with a damp cloth and mild detergent Do not use abrasive materials or solvents 2 Clean the terminals with a cotton swab with detergent as dirt or mo...

Page 11: ...and or installation 2 This warranty does not cover cosmetic damage due to misuse or neglect This includes paint damage scratches cracks or other superficial marks related to improper use 3 Failures ar...

Page 12: ...Stahl Tools Last Revised 9 15 2017 stahltools com...