Operation, Installation and Maintenance Manual for 6018/11 - Series
ID-No.:
226765 / 6018605300
Publication Code: 2017-08-31:BA00.lll.en.02 Page - 19 - of 22
•
Close the battery case.
•
Resetting of the capacity error will be indicated on the LED display for 5 seconds by blinking red/green.
•
The error is reset.
Further error indications will be reset directly after troubleshooting.
If the error cannot be eliminated using the mentioned procedures:
•
Contact R. STAHL Schaltgeräte GmbH.
For fast processing, have the following information ready:
•
Type and serial number
•
Purchase information
•
Error description
•
Intended use (in particular input / output wiring)
10.
Maintenance, repair & returning of the device (as per EN60079-17 & as per EN60079-19)
WARNING
Unauthorized work being performed on the device!
Risk of injuries and material damage!
•
Work performed on the device must only be carried out by appropriately authorized and trained personnel.
•
Risk of electric shock or malfunctioning of the device due to unauthorized work!
Non-compliance can result in severe injuries and material damage.
•
Work performed on the device must only be carried out by appropriately authorized and qualified electricians.
10.1
Maintenance
•
Observe the relevant national regulations in the country of use.
•
Periodic Cleaning & Maintenance to be carried out – for details look into the section “10.1.2” of this manual
•
To protect the battery from deep discharge, keep the Battery Electrically Disconnected, when the light fixture is not in
use for a longer period (more than 4-Weeks).
•
Consult the relevant national regulations to determine the type and extent of inspections.
•
Adapt inspection intervals to the operating conditions.
•
To protect the battery from deep discharge, keep the Battery Electrically Disconnected, when the light fixture is
not in use for a longer period (more than 4-Weeks).
The following tests and measures must be carried out during regular maintenance.
Check
Measures
•
the permissible ambient temperature
•
If exceeding the permissible ambient temperature or falling below the device must
be taken out of operation.
•
the enclosure components for
formation of cracks and damage.
•
Replace the exchangeable enclosure components. If the enclosure components are
non-exchangeable, the device must be taken out of operation.
•
its intended use
•
If the device is not used according to its intended use, it must be taken out of
operation.
•
the cables for ageing and damage
•
Replace damaged or aged cables.