Operation, Installation and Maintenance Manual for 6018/11 - Series
ID-No.:
226765 / 6018605300
Publication Code: 2017-08-31:BA00.lll.en.02 Page - 20 - of 22
•
the seals for ageing and damage
•
Replace damaged, aged and porous seals and completely change enclosure
components with foamed seal.
•
if the conductors are clamped
properly
•
Clamp loose conductors tightly.
10.1.1
Replacement of lamps
Only use fluorescent lamps with pins made of brass.
1.
Insert both the lamp bases into the holder guide slots until the stop is reached.
2.
Move lamp to its operating position by turning it to the right or the left.
3.
Dismounting is carried out in reverse order.
Important notes:
•
The lamp bases and pins must be undamaged.
•
The holders have a spring-loaded length adjustment facility of 2.5 mm each.
•
Make sure that the lamp has been fitted properly. When it has been turned, the lamp
is locked in position.
•
Replace the lamps in due time.
•
Observe the service life specified by the manufacturer.
•
EOL- safety shutdown: The EB switches off the lamp at the end of the service life.
10.1.2 Replacement of Battery
WARNING
Danger due to sparking!
Explosion protection is impaired!
Carry the battery Carefully.
Risk of electric shock or malfunctioning of the device due to unauthorized work!
Non-compliance can result in severe injuries and material damage.
•
Work performed on the device must only be carried out by appropriately authorized and qualified electricians.