5
Technical Data
Explosion Protection Certificats
ATEX, IEC Ex, PESO,
Zone Classification
Zone 1, 2, 21 & 22
Explosion Protection Type
Equipment protection by type of protection “n”, Equipment dust ignition protection by enclosure “t”
IECEx
IECEx BVS 16.0019
Ex eb db mb IIC T4 Gb
Ex tb IIIC T 80 °C Db
ATEX
BVS 16 ATEX E 025
II 2 G Ex eb db mb IIC T4 Gb
II 2 D Ex tb IIIC T 80 °C Db
Electrical Data
Ballast
Lamp Start
Warm start
Voltage
110 ... 127 V AC + 10% (6018/11..-....-.
6
..-..)
220 ... 254 V AC + 10% (6018/11..-....-.
7
..-..)
Frequency
50 … 60 Hz
Lamp standard
IEC 60081
Lamp power
18, 36 W
Nominal current
2x 18 W 180 mA
2x 36 W 350 mA
Battery set :
Emergency
light
service
time
Battery
Type
Variants
Battery
capacity
Emergency
light service
time
Emergency lighting power
Lights 18 W
Lights 36 W
Ni-Cd-
Battery
6018/11..-....-.
6
..-..
6018/11..-....-.
7
..-..
6V/7Ah
1.5 h
100%
60%
6V/7Ah
3 h
60%
30%
Emergency Mode
In emergency mode, when operated on battery only one fluorescent lamp will be driven
(The one which is marked with a Green Dot – refer section 4.2 of this manual).
Battery Full Charging Time
25 Hours (Only First time charging for the new battery).
Consecutive charging time will be less than 24 Hours, depending on the discharge level.
Replacing the battery
When opening the battery enclosure, the connection between the battery set and the emergency
Light electronics is disconnected.
The battery set can be replaced after disconnecting the plug-in contacts.
Power factor cos
∅
Cos
∅
> 0.93
Ambient Operating Temp. (Ta)
Normal Operation
-20 °C ≤ T
amb
≤ +50 °C
Emergency light Operation
-20 °C ≤ T
amb
≤ +50 °C
During charging
-05 °C ≤ T
amb
≤ +50 °C
Mechanical data
Degree of protection
IP 65
IP66 for Light Fitting with Frame
IP 64 with breathing gland 8162
acc. IEC 60598
Protection class
I (with internal PE connection)
Material
Enclosure
Sheet steel powder coated
Stainless steel SS304 (V2A | 1.4301) brushed
Stainless steel SS316L (V4A | 1.4404) brushed
Colour
White, similar RAL 9016
Lamp Cover
Toughened Glass.
Gasket
Silicon foam gasket in the luminaire enclosure
Luminaire locking
Central locking can be opened/closed using a socket key M5 Hex socket head driver
Mounting / Installation
Cable glands
2x M20/M25 left and 1x M20/M25 right, 1x cable glands, 1x cable red plug and 1 stopping plugs as standard