2016-12-13·BA00·III·en·05
Safety
5
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Terminal Box
Series 8150/1, Series 8150/2
neering and modification
• Mounting/dismounting the device
• Installation
• Commissioning
• Maintenance, repair, cleaning
Specialists who perform these tasks must have a level of knowledge that complies with
the relevant national standards and regulations.
Additional knowledge is required for activities in hazardous areas! R. Stahl recommends
a level of knowledge described in the following standards:
• IEC/EN 60079-14 (Electrical installations design, selection and erection)
• IEC/EN 60079-17 (Inspection and maintenance of electrical installations)
• IEC/EN 60079-19 (Equipment repair, overhaul and reclamation)
3.3
Residual risks
3.3.1 Explosion hazard
An explosion hazard cannot be entirely ruled out in hazardous areas despite the device
having a state-of-the-art design.
Perform all work steps in hazardous areas with the utmost care at all times!
Possible moments of danger (residual risks) can be categorised according to the following
causes:
Mechanical damage
The device can be pressed or scratched during transport, mounting or commissioning,
causing it to no longer be leak-tight. Such damage can, for example, render the device's
explosion protection partially or fully ineffective. This can result in explosions causing fatal
or severe injuries to persons.
Observe the weight and the maximum load-bearing capacity of the device;
see specifications on the packaging.
Transport the device only in the original packaging or in equivalent packaging.
Use transporting or lifting equipment which is suitable for the size and weight of the device
and can reliably carry the weight of the device.
Check the packaging and the device for damage. Report any damage to R. STAHL
immediately.
Store the device in the original packaging in a dry (no condensation) and stable position
which is safe from vibrations.
Do not damage the enclosure, built-in components or seals during mounting.
Excessive heat-up or electrostatic charge