6
Engineering
7
Transport and Storage
• Transport and store the device only in the original packaging.
• Store the device in a dry place (no condensation) and vibration-free.
• Do not drop the device.
8
Mounting and Installation
The device is approved for use in gas explosion hazardous areas of Zones 1 and 2 and
dust explosion hazardous area of Zones 21 and 22 and in safe areas.
DANGER
Explosion hazard due to too high temperature in the cabinet!
Non-compliance results in severe or fatal injuries!
• Install and adjust the cabinet in such a way that it is always
operated within the permissible temperature range.
DANGER
Explosion hazard due to installation without approved field enclosure!
Non-compliance results in severe or fatal injuries!
• In hazardous areas (Zones 1, 2 21 or 22), the device must be
installed in an enclosure which meets the requirements of
IEC/EN 60079-7, IEC/EN 60079-15 or IEC/EN 60079-31.
DANGER
Explosion hazard due to incorrect installation of the device!
Non-compliance results in severe or fatal injuries.
• Carry out installation strictly according to the instructions and
national safety and accident prevention regulations to maintain the
explosion protection.
• Select and install the electrical device so that explosion protection
is not affected due to external influences, i.e. pressure conditions,
chemical, mechanical, thermal and electric impact such as
vibration, humidity and corrosion (see IEC/EN 60079-14).
• The device must only be installed by trained qualified personnel
who is familiar with the relevant standards.