253215 / 941960310090
2017-04-21·BA00·III·en·01
Technical Data
11
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Bus-Carrier for linking device
Series 9419/0..-LD1-..E1
5
Technical Data
Explosion Protection
Global (IECEx)
Gas
IECEx BVS 09.0042X
Ex nA nC IIC T4 Gc
Europe (ATEX)
Gas
BVS 09 ATEX E 100 X
E
II 3 G Ex nA nC IIC T4 Gc
Certifications and certificates
Certificates
IECEx, ATEX
Ship approval
In progress
Further parameters
Installation
Zone 2, safe area
Further information
see respective certificate and operating instructions
Technical Data
Electrical data
Auxiliary power
Nominal voltage
U
N
24 V DC
Rated current I
N
(
8 A
Voltage range
19 to 32 V
Residual ripple
within voltage
range
(
3.6 V
SS
Redundant supply yes, diode-decoupled
Polarity reversal
protection
yes
Operation
indication
2 LEDs, green ("pri", "red")
Electromagnetic
compatibility
Tested under the following standards and regulations:
EN 61326-1 Use in industrial environment;
Error detection
Power fail (pri / red)
Contact "PF" (30 V / 100 mA) closed in good conditions
Diagnostics
Contact "Dia" (30 V / 100 mA) closed in good conditions
Ambient conditions
Ambient temperature -20 to +60 °C
Storage temperature -40 to +80 °C
Relative humidity
(no condensation)
< 95%
Use at the height of
< 2000 m