background image

 

 

 

Installation Manual 

SERIES 400 

Panel PC

 

SERIES 500 

Thin 

Clients

 

SERIES 600 

KVM Systems 

 

Device platform MANTA 

 

ET-xx7 / MT-xx7 

 

 
 

 
 
 
 
 
 

 

 

HW-Rev. ET-4x7-*-BT: 

01.03.02 

 

HW-Rev. ET-5x7-*-BT: 

01.03.02 

 

HW-Rev. ET-6x7: 

01.03.00 

 

HW-Rev. MT-4x7-*-BT: 

01.01.02 

 

HW-Rev. MT-5x7-*-BT: 

01.01.02 

 

HW-Rev. MT-6x7: 

01.01.00 

 
 
 

Installation Manual version: 

01.00.01 

 

Issue date: 

05.01.2018 

 

 

Summary of Contents for ET-xx7

Page 1: ...ERIES 600 KVM Systems Device platform MANTA ET xx7 MT xx7 HW Rev ET 4x7 BT 01 03 02 HW Rev ET 5x7 BT 01 03 02 HW Rev ET 6x7 01 03 00 HW Rev MT 4x7 BT 01 01 02 HW Rev MT 5x7 BT 01 01 02 HW Rev MT 6x7 01 01 00 Installation Manual version 01 00 01 Issue date 05 01 2018 ...

Page 2: ... the publisher This document may be subject to change dates dimensions weight constructions drawings images Any warranty claims are limited to the right to demand amendments Liability for any damage that might result from the contents of these instructions or all other documentation is limited to clear cases of premeditation We reserve the right to change our products and their specifications at a...

Page 3: ... 6 5 Mounting 7 5 1 Mounting options 7 5 2 Recommended mounting type 8 5 3 Assembly notes 9 6 Tools 9 7 Mechanical Installation 10 7 1 Dimensions 10 7 2 Mounted on stand 12 7 2 1 View 12 7 2 2 MPFL Stand 12 7 2 3 Mounting Step by step 13 8 Electrical Installation 18 8 1 Connection of the X10 power supply 18 8 2 Earthing of stand 18 8 3 Ethernet interface X16 19 8 3 1 TX or 2TX with SERIES 400 500 ...

Page 4: ...h the multi touch functions of the operating system and the application Switch off the device for cleaning and maintenance Conductive liquids on the touch screen can result in incorrect or phantom operations This applies in particular to salt water Avoid contamination of the touch screen surface with salt water Protect the device against rain snow and splashes since excessive amounts of standing o...

Page 5: ...stems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 Page 5 of 24 3 Enclosure types HSG xx7 VxA FR HSG xx7 VxA CFR with front door as standard with front door for cleanroom HSG xx7 VxA BD HSG xx7 VxA FR HSG xx7 VxA CFR with rear door Backdoor for wall mounting ...

Page 6: ... MT xx7 Versions mounted on stand or elbow Page 6 of 24 R STAHL HMI Systems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 4 Versions mounted on stand or elbow mounted upright on elbow mounted hanging from elbow MPFL stand ...

Page 7: ...7_en_V_01_00_01 docx 05 01 2018 Page 7 of 24 5 Mounting In regards of different applications and ambient conditions we recommend following installation types 5 1 Mounting options Mounted on stand Ceiling mounting Elbow upright mounting Mounted hanging from elbow Wall mounting ...

Page 8: ...with without external keyboard No restriction Ceiling mounting with MPFL stand with without external keyboard No restriction Mounted on elbow standing with without external keyboard No restriction Mounted on elbow hanging with without external keyboard No restriction Wall mounting with without external keyboard No restriction Vibration sinusoidal acc to IEC 60068 2 6 5 13 2 Hz 1 mm 13 2 100 Hz 0 7...

Page 9: ...and wall bracket must be mounted with at least 4 fastening points The type of wall fixing used must be suitable for the wall material 6 Tools 1x side cutter 1x wire stripping knife 1x wire stripper 1x spanner AF 10 1x spanner AF 13 1x spanner AF 14 1x spanner AF 24 1x spanner AF 30 1x Phillips screwdriver size 1 1x Phillips screwdriver size 2 1x flat bladed screwdriver 2 5 mm 1x Allen key 5 mm Mou...

Page 10: ... GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 7 Mechanical Installation Always have two people mount the device 7 1 Dimensions Dimensions in mm HSG xx7 VxA FR A B C D E F G H I 740 568 190 720 304 400 78 34 270 HSG xx7 VxA CFR A B C D E F G H I 720 627 190 720 304 406 78 34 270 CAUTION ...

Page 11: ...SG xx7 VxA W X Mounting tongues for wall mounting a Alternative mounting position of the mounting tongues Enclosure types FR and CFR are used for wall mounting The dimensions of these enclosures are listed in the above tables Choose suitable mounting screws rawlplugs and bolts depending on the actual local requirements and possibilities Dimensions mounting tongue A B C D E F 30 55 35 10 5 10 5 18 ...

Page 12: ...12 of 24 R STAHL HMI Systems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 7 2 Mounted on stand 7 2 1 View 7 2 2 MPFL Stand All dimensions in mm Stand A B C D E F G H 1216 265 200 135 20 101 Ø 60 3 Ø 88 9 Cable glands Gl1 Gl2 Gl3 M25 x 1 5 M25 x 1 5 M20 x 1 5 ...

Page 13: ..._ET_MT xx7_en_V_01_00_01 docx 05 01 2018 Page 13 of 24 7 2 3 Mounting Step by step Choose suitable mounting screws rawlplugs and bolts depending on the actual local requirements and possibilities Earth of the stand 8x Ø16 see dimensions stand 2 1 NOTE see 8 1 Connection power supply ...

Page 14: ... 14 of 24 R STAHL HMI Systems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 A mounting holes hanging mounting B mounting holes standing mounting 3 Operator interface enclosure D Mounting holes in the enclosure of the operator interface Coupling pre mounted 3 ...

Page 15: ...Installation Manual ET MT xx7 Mechanical Installation R STAHL HMI Systems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 Page 15 of 24 C M6 allen screw E Mounting coupling F Stand wall bracket or 4 5 ...

Page 16: ...Installation Manual ET MT xx7 Mechanical Installation Page 16 of 24 R STAHL HMI Systems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 6 7 tighten all 4 screws with a torque of 10 Nm ...

Page 17: ...MT xx7 Mechanical Installation R STAHL HMI Systems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 Page 17 of 24 1 Connection bolt for equipotential bonding Already wired to the multiple connection 2 in operator stations OS 8 ...

Page 18: ...Power supply 24 VDC 2 Power supply 0 VDC 3 Equipotential bonding enclosure AC 1 Phase conductor L 100 240 VAC 2 Neutral conductor N 100 240 VAC 3 Protective conductor enclosure Connect only AC devices look at device label to 100 240 VAC mains 8 2 Earthing of stand see 7 2 3 step 2 1 Stand mounting plate 2 Washer 2x 3 Toothed washer 4 Hexagon screw M6x16 5 Split washer 6 Cable lug with eyelet 9 Lab...

Page 19: ...16 8 3 1 TX or 2TX with SERIES 400 500 Pin Signal Colour Note Connection 1 TRD0 White Orange twist 100Base TX interface 2 TRD0 Orange 3 TRD1 White Green 4 TRD1 Green 5 TRD2 White Orange 2nd 100Base TX interface only for option 2TX 6 TRD2 Orange 7 TRD3 White Green 8 TDR3 Green 9 SHLD Screen Connect screen separately to the screen connection rail see diagram 11 ...

Page 20: ... 2018 8 3 2 TX with SERIES 600 8 3 2 1 Cable adaptation Pin Signal Colour Note Connection 1 TRD0 White Orange twist Ethernet interface 2 TRD0 Orange 3 TRD1 White Green 4 TRD1 Green 5 TRD2 White Orange 6 TRD2 Orange 7 TRD3 White Green 8 TDR3 Green 9 SHLD Screen Connect screen to the screen connection rail see diagram 12 Right Wrong ...

Page 21: ...Installation Manual ET MT xx7 Electrical Installation R STAHL HMI Systems GmbH IM_ET_MT xx7_en_V_01_00_01 docx 05 01 2018 Page 21 of 24 8 4 Ethernet optical fibre interface Rx Tx 13 ...

Page 22: ...Release Notes contains all the changes made in every version of the Instructions Version 01 00 00 First edition Version 01 00 01 Correction of version number in section Release Notes Changing HW Rev at xT 4x7 BT and xT 5x7 BT at cover Changing picture at cover Correction data and content according to enclosure for wall mounting Text layout and formal corrections ...

Page 23: ......

Page 24: ...MI Systems GmbH Adolf Grimme Allee 8 D 50829 Köln Phone switchboard 49 0 221 76 806 1000 Hotline 5000 Fax 4100 E mail switchboard office stahl hmi de hotline support stahl hmi de www r stahl com www stahl hmi de ...

Reviews: