Explanation of the symbols

4

243137 / 640260300020

2015-12-22·BA00·III·en·05

Linear Luminaire with LED

Series EXLUX 6402/2

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

2

Explanation of the symbols

2.1

Symbols in these operating instructions

2.2

Warning notes

Warning notes must be observed under all circumstances, in order to minimize the risk 

due to construction and operation. The warning notes have the following structure:

• Signalling word: DANGER, WARNING, CAUTION, NOTICE

• Type and source of danger/damage

• Consequences of danger

• Taking countermeasures to avoid the danger/damage

Symbol

Meaning

Tips and recommendations on the use of the device

General danger

Danger due to explosive atmosphere

Danger due to energised parts

DANGER

Danger to persons

Non-compliance with the instruction results in severe or fatal injuries  

to persons.

WARNING

Danger to persons

Non-compliance with the instruction can result in severe or fatal injuries  

to persons.

CAUTION

Danger to persons

Non-compliance with the instruction can result in light injuries to persons.

NOTICE

Avoiding material damage

Non-compliance with the instruction can result in material damage to the device and / or 

its environment.

Summary of Contents for EXLUX 6402/2 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www stahl ex com EN Linear Luminaire with LED Series EXLUX 6402 2 ...

Page 2: ...g notes 4 2 3 Symbols on the device 5 3 Safety notes 5 3 1 Operating instructions storage 5 3 2 Safe use 5 3 3 Intended Use 5 3 4 Modifications and alterations 5 4 Function and device design 6 4 1 Function 6 4 2 Device design 6 5 Technical data 8 6 Transport and storage 11 7 Mounting and installation 12 7 1 Dimensions fastening dimensions 12 7 2 Mounting dismounting operating position 13 7 3 Insta...

Page 3: ...tions See certificates and EC Declaration of Conformity www stahl ex com The device has IECEx approval See IECEx homepage http iecex iec ch R Stahl Schaltgeräte GmbH Am Bahnhof 30 74638 Waldenburg Germany R STAHL P LTD Plot No 5 Malrosapuram Road Sengundram Indl Area Singaperumal Koil Kancheepuram Dist Tamil Nadu 603 204 INDIA Phone Fax Internet E mail 49 7942 943 0 49 7942 943 4333 www stahl ex c...

Page 4: ...e and source of danger damage Consequences of danger Taking countermeasures to avoid the danger damage Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere Danger due to energised parts DANGER Danger to persons Non compliance with the instruction results in severe or fatal injuries to persons WARNING Danger to persons Non compliance wit...

Page 5: ... and approved purpose only We cannot be held liable for damage caused by incorrect or unauthorized use or by non compliance with these operating instructions Before installation and commissioning make sure that the device is not damaged Work on the device installation maintenance overhaul repair may only be carried out by appropriately authorized and trained personnel 3 3 Intended Use The luminair...

Page 6: ...n and device design 4 1 Function for lighting areas work spaces and objects switching off the equipment by means of a central lock optional when the luminaire is opened 4 2 Device design DANGER Explosion hazard due to improper use Non compliance results in severe or fatal injuries Use the device only according to the operating conditions described in these operating instructions 16346E00 4 5 6 7 1...

Page 7: ...2 2 EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN 16349E00 1 Connection terminal mounting plate internal wiring 6 Luminaire enclosure 2 Ballast 7 Mounting plate 3 Translucent cover 8 LED PCB 4 Cable gland 9 Diffuser optional accessories 5 Connection terminal luminaire customer wiring 7 8 9 ...

Page 8: ...ates IECEx ATEX Technical Data Electrical data Ballast AC 220 240 V 10 50 60 Hz DC 200 250 V 10 Inrush current Ipeak 53 5 A Δt 124 8 ms maximum number of luminaires per miniature circuit breaker Power factor 0 93 Degree of protection IP66 IP67 IEC 60598 Protection class I with internal PE connection Impact strength IK code IK10 IEC 62262 Disconnection of the light When opening the luminaire Switch...

Page 9: ...0 6402 22 4 5 0 6402 21 2 5 1 6402 22 4 5 1 Power consumption W 28 52 28 52 Colour rendering Ra 80 80 70 70 Colour temperature K 5000 5000 5700 5700 without diffuser Luminous flux lm 2919 5375 3150 5800 Luminaire efficiency lm W 105 103 113 111 Light output ratio 85 85 92 92 with diffuser Luminous flux lm 2558 4670 2760 5040 Luminaire efficiency lm W 92 90 99 97 Light output ratio 75 76 81 82 Ta 2...

Page 10: ...or metal cable entries Attention cable entries must be ordered separately Special max 4 bores for M20 M25 NPSM max 2 bores for NPT Metal cable glands M20 x 1 5 M25 x 1 5 earthing of the metal cable entries by means of metal plates Standard Spring clamp terminals 5 pole L1 L2 L3 N PE with through wiring Clamping range 1 x 0 75 4 mm2 solid finely stranded 2 free clamping units for each pole availabl...

Page 11: ...nd store the device only in the original packaging Store the device in a dry place no condensation and vibration free Do not drop the device Assembly Technical Data Standard luminaire Standard 2 x M8 insert nuts in the enclosure Special Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting variable mounting distances for luminaires L 700 mm 32...

Page 12: ...tection Select and install the electrical device so that explosion protection is not affected due to external influences i e pressure conditions chemical mechanical thermal and electric impact such as vibration humidity and corrosion see IEC EN 60079 14 The device must only be installed by trained qualified personnel who is familiar with the relevant standards Dimensional Drawings All Dimensions i...

Page 13: ...e following processes activities should be avoided accidental friction particle currents DANGER Explosion hazard due to inadmissible heating Non compliance results in severe or fatal injuries Avoid external heat sources and or direct sunlight risk of change of temperature class or change of maximum permissible surface temperature Do not exceed the maximum ambient temperature due to external heat s...

Page 14: ...epth 10 mm 0 39 15442E00 15447E00 Mounting bracket Top rail Lateral mounting pockets for variable suspension points When mounting the luminaire using top rails ensure that the mounting surface is flat Otherwise the enclosure might be mounted in a warped twisted way The result is leakage of the luminaire and difficulties in replacing the translucent cover L2 Version L2 mm inches 28 W 400 15 75 52 W...

Page 15: ... Schaltgeräte GmbH with integrated mounting rail providing reliable and stable four point fixing Wall bracket mounting 15455E00 15443E00 Version L4 mm inches L mm inches 28 W 320 12 60 80 3 15 52 W 670 26 38 130 5 12 In case of point suspension using pipe clamps R STAHL Schaltgeräte GmbH does not guarantee the strength and tightness of the luminaire 15515E00 15517E00 Version L4 mm inches L mm inch...

Page 16: ...unting sur face is flat Otherwise the enclosure might be mounted in a warped twisted way The result is leakage of the luminaire and difficulties in replacing the translucent cover For pipe clamp mounting use the solution of R STAHL Schaltgeräte GmbH with integrated mounting rail providing reliable and stable four point fixing In case of point suspension using pipe clamps R STAHL Schaltgeräte GmbH ...

Page 17: ...ctor plate 7 3 2 Electrical connections Electrical connection Observe the maximum clamping possibility of the connecting terminals see chapter Technical data For optional screw type terminals two conductors per clamping unit can be clamped ingoing and outgoing wiring Note Clamping must be carried out precisely Do not clamp any part of the conductor insulation Do not interchange the conductors Obse...

Page 18: ...with installed cable glands and stopping plugs from R STAHL Schaltgeräte GmbH Standard Spring clamp terminals up to 4 mm2 Optional Screw type terminals up to 4 mm2 finely and extra finely stranded and 6 mm2 solid Stripping length 10 11 mm Stripping length 10 11 mm 15516E00 15438E00 NOTE Through wiring with 2 5 mm 2 cross section for max 16 A Tightening torque Connection thread Pressure screw Cable...

Page 19: ...has been used the cable entries and stopping plugs have been securely tightened the cables are correctly connected the connection has been performed correctly all screws and nuts are tightened according to regulations the connection chamber is clean the device is not damaged no foreign bodies are inside the device the device is sealed according to regulations the LED assembly and the diffusor are ...

Page 20: ...ly authorized and qualified electricians Observe the relevant national regulations in the country of use Check Measures the permissible ambient temperature If exceeding the permissible ambient temperature or falling below the device must be taken out of operation the enclosure components for formation of cracks and damage Replace the exchangeable enclosure components If the enclosure components ar...

Page 21: ...g with the service form in the original packaging to R STAHL Schaltgeräte GmbH 10 Disposal Observe national and local regulations and statutory regulation regarding disposal Separate materials when sending it for recycling Ensure environmentally friendly disposal of all components according to the statutory regulations 11 Accessories and Spare parts DANGER Explosion hazard due to improper repair N...

Page 22: ......

Page 23: ......