Safety notes

3.1

Operating instructions storage

• Read the operating instructions carefully and store them at the mounting location of 

the device.

• Observe applicable documents and operating instructions of the devices to be  

connected. 

3.2

Safe use

• Read and observe the safety notes in these operating instructions!

• Observe characteristic values and rated operating conditions on the rating and data 

plates!

• Observe additional information plates on the device!

• Use the device in accordance with its intended and approved purpose only!

• We cannot be held liable for damage caused by incorrect or unauthorized use or by 

non-compliance with these operating instructions.

• Before installation and commissioning, make sure that the device is not damaged!

• Work on the device (installation, maintenance, overhaul, repair) may only be carried 

out by appropriately authorized and trained personnel.

3.3

Intended Use

The luminaire L402/2 is equipment

• for stationary mounting

• can be used indoors and outdoors

• for lighting areas, work spaces and objects

4

Function and device design

4.1

Function

• for lighting areas, work spaces and objects

Symbol

Meaning

05594E00

CE marking according to the current applicable directives.

Summary of Contents for EXLUX L402/2 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www r stahl com EN Linear Luminaire with LED Series EXLUX L402 2...

Page 2: ...s 4 2 2 Warning notes 4 2 3 Symbols on the device 5 3 Safety notes 5 3 1 Operating instructions storage 5 3 2 Safe use 5 3 3 Intended Use 5 4 Function and device design 5 4 1 Function 5 4 2 Device des...

Page 3: ...1 3 Conformity with standards and regulations See certificates and EC Declaration of Conformity www r stahl com R Stahl Schaltger te GmbH Am Bahnhof 30 74638 Waldenburg Germany R STAHL P LTD Plot No 5...

Page 4: ...N NOTICE Type and source of danger damage Consequences of danger Taking countermeasures to avoid the danger or damage Symbol Meaning Tips and recommendations on the use of the device General danger Da...

Page 5: ...data plates Observe additional information plates on the device Use the device in accordance with its intended and approved purpose only We cannot be held liable for damage caused by incorrect or unau...

Page 6: ...design 6 259910 L40260300020 2017 09 18 BA00 III en 00 Linear Luminaire with LED Series EXLUX L402 2 EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN 4 2 Device design 16346...

Page 7: ...2 EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN 16349E00 1 Connection terminal mounting plate internal wiring 6 Luminaire enclosure 2 Ballast 7 Mounting plate 3 Transluce...

Page 8: ...ck optional when opening the central lock all poles of the voltage supply to the ballast are disconnected contacts of the switching element are positive opening they can only be switched on again when...

Page 9: ...100 000 h 100 000 h 50 000 h LxByCz At the end of the service life Luminous flux decrease to x percent up to y percent of all luminaires fall below x up to z percent of all luminaires break down compl...

Page 10: ...Light fittings are equipped with internal through wiring Ingoing and outgoing leads can be connected to the opposite sides Terminals see techn data Wiring cross section 2 5 mm2 for max 16 A Optional w...

Page 11: ...aused by condensation Non compliance can result in material damage operate the luminaire continuously or periodically over extended periods of time avoid thermal bridges Dimensional Drawings All Dimen...

Page 12: ...The luminaire is suitable for wall and ceiling mounting In event of wall mounting in outdoor areas avoid installation with central lock at top The mounting position with upward light emission in outd...

Page 13: ...ing rail providing reliable and stable four point fixing When mounting the luminaire using top rails ensure that the mounting surface is flat Otherwise the enclosure might be mounted in a warped twist...

Page 14: ...inaire and difficulties in replacing the translucent cover For pipe clamp mounting use the solution of R STAHL Schaltger te GmbH with integrated mounting rail providing reliable and stable four point...

Page 15: ...ening dust protection Note Version without switch Disconnect the luminaire from the power supply and secure it against being switched on again Version with switch The luminaire is positively disconnec...

Page 16: ...not interchange the conductors Observe the technical regulations when connecting the conductor Clamp the conductor firmly The terminal cover of optional screw type terminals does not have to be remov...

Page 17: ...plugs the required tightening torques the range of the permissible cable diameter 8 Commissioning Before commissioning ensure that the device has been installed according to regulations the power sup...

Page 18: ...uthorized and qualified electricians Observe the relevant national regulations in the country of use Check Measures the permissible ambient temperature If exceeding the permissible ambient temperature...

Page 19: ...device when repair service is required On the internet site www stahl ex com under Downloads Customer service Download the service form and fill it out Send the device along with the service form in t...

Page 20: ......

Reviews: