- 20 -
EN
Button
Function
Used to display the setting, in the programming cycle is used to select the
parameter or confirm the operation.
With this arrow you can display the last alarm, in the programming cycle,
you can scroll through the parameters or increase the displayed value.
The arrow turned down is used to display the last alarm, during the
programming cycle, to scroll through the parameters, or to decrease the
displayed setting.
DEF
This button is used to manually start the defrosting process.
Combinations of buttons
Used to lock and unlock the keyboard.
Used to enter the programming mode.
Return to display the temperature in the chamber.
6.1.
Description of indicator lights
On
The compressor is on.
Flashes
The programming mode has been activated.
On
The defrosting has been activated.
Flashes
Programming mode, dripping in progress.
o
F
o
C
On
Fahrenheit degrees
Celsius degrees
6.2.
How to check the duration of the alarm and the minimum and maximum temperature
If an alarm symbol appears on the display, to see the type of alarm, min (max) temperature, the duration of
the alarm, proceed as follows
1.
Press the arrow up or arrow down button
2.
The display will show the following message „HAL” for high temperature alarm, „LAL” for low tempera-
ture alarm. Then „tIM” (time) displays the duration of the alarm in minutes
3.
The next step is to return to the temperature display
6.3.
Deleting constantly occurring saved alarm
1.
Press down the SET button and hold it for more than 3 seconds, in the meantime the saved alarm is
displayed (the display will show rSt message);
2.
To confirm the operation, „rSt” message will start flashing and the normal temperature will be display-
ed