- 9 -
EN
4. TECHNICAL SPECIFICATION
Model
Dimensions
Capacity net Climatic Class Temperature
Refrigerant
Power
Voltage
883101
574x564x845 mm
93 l
SN/N/ST/T
≤-18
o
C
R600a / 52g
105W
230 V / 50 Hz
883201
950x564x845 mm
190 l
R600a / 65g
120 W
883301
1116x644x845 mm
282 l
R600a / 75g
130 W
883401
1275x740x825 mm
354 l
R600a / 86g
110 W
883501
1535x740x825 mm
488 l
R600a / 100g
125 W
The device contains coolant R600a - natural, ecological, flammable gas.
Take special care when transporting and installing the device to avoid damaging the cooling circuit.
If a leak is revealed, refrain from using devices/items that could cause sparks or fire and ventilate the room. To
avoid the formation of a flammable gas mixture in the event of a leak from the refrigeration system, install the
device in a room with area of 1m
3
per every 8 g of the coolant. The amount of coolant is given in „TECHNICAL
DATA” and on the nameplate.
5. CONTROL PANEL
1
2
3
4
1.
Power supply light on the device
2.
Device operation light
3.
Alarm - switches on when the temperature inside the chamber is
higher than the set point.
4.
Temperature regulator knob
5.1.
Adjusting temperature
The temperature inside the freezer is maintained by a thermostat. It can be adjusted with the thermostat knob.
Position 1
= highest cooling efficiency
Position 2
= lowest cooling efficiency
Temperature inside the freezer depends on the thermostat setting, how often the lid is opened, how much frozen food is inside
and ambient temperature. The temperature is displayed on the control panel.
Position
7
is used to quickly cool the freezer compartment. After about 24 hours, it is recommended to move to position
4
.
5.2.
ON /OFF
It is advised that the freezer is cleaned before first use. The freezer should be switched on about 6 hours before any products are
placed inside.
Switching the freezer off
Turn the thermostat knob to „
0
”. In order to completely deactivate the device pull the plug from the electrical socket.
5.3.
Deicing / defrosting
After extensive use the inside of the freezer can become covered with a thick layer of frost and ice. It can cause increased power
usage. The freezer should be defrosted regularly.
Before defrosting remove the contents of the freezer and turn thermostat to „
0
”.
Remove the plug from the water drainage inside the freezer and the plug on the right side of the device. Remember that water
will flow to the floor. The lid should be opened during defrosting. Water which remains in the freezer should be removed with a
cloth or sponge. Clean the freezer. Do not use any mechanical devices or any other artificial chemicals for defrosting.
6. CLEANING
The inside, walls and equipment of the freezer should be washed with warm water and a mild detergent.
Do not use cleaning detergents which include sand, acid or chemical solvents.
Do not use steam cleaning devices.
Be careful when washing the freezer with water. Do not allow any water to access its electrical parts and ventilation.
After washing wipe the freezer dry.
Ventilation grill should be cleaned regularly with a brush or a vacuum cleaner. Any lodging of dust will cause higher power usage.
While cleaning be careful not to damage any wiring or other elements.