EN
Distance „H” between the sleeve and the burner housing
3.
Replacing the pilot nozzle: unscrew the „D” screw from the bottom of the pilot body, then unscrew
the nozzle and install the corresponding nozzle. Then adjust the „E” air shutter on the pilot’s body in ac
-
cordance with Table 4.1
Pilot position
Pilot components:
A.
Thermocouple
B.
Remote
C.
Electrode
D. Nozzle bolt
Air shutter on the
pilot’s body
Pilot nozzle
CAUTION: The fryer is operating at a temperature set on the valve (110-190 °C). Setting the tem
-
perature on the valve causes the oil to heat up to a preset temperature, e.g. 190 °C (main burners
switching off), then cooling the oil below the preset temperature (throwing in frozen french fries)
causes the main burners to reactivate and the oil is heated up
After changing the type of gas supplying the appliance - remember:
•
Place a new information sticker on the appliance to adapt to the new supply.
•
Use red paint to mark the new position of moving parts, e.g. the air control sleeve
•
Check the tightness of connections
•
Check the position and operation of the main burners: color, shape and flame stability.
Note for maintenance staff: When replacing the safety thermostat, insert the sensor so that only
the capillary tube hides in the socket; whereas when replacing the minisit valve, insert the sensor
fully into the socket.