Make sure that the gas pipe does not pass near hot areas and that it is not exposed to possible tractions, torsions
or crushing.
The gas supply pipe (rigid or flexible) must comply with current national regulations and, in addition, must un-
dergo appropriate periodic inspections, as well as be replaced if necessary.
3.6.
Connection for flue gas evacuation
The gases resulting from the combustion of the gas must be evacuated to the outside by installing a chimney with natural draft,
or by placing the oven under an extraction hood.
Type evacuation B23:
by this way, the combustion gases are evacuated to the outside through a natural draft chimney provided
with a non-return valve.
90°
O
D
O
D
For any doubt related to the assembly process necessary for gas evacuation, please refer to the technical
installation manual.
It is advisable to install a cap at the end of the chimney in order to prevent rainwater from entering the device and
prevent possible air returns caused by strong wind.
The temperature of the flue gases can reach 500 °, so we recommend using stainless steel pipe or similar material
resistant to high temperature.
Type evacuation A3:
by this way, the flue gases are evacuated to the outside through a suction hood. The minimum distance to
keep between the oven and the hood will be at least 50cm.