EN
16
EN
17
1.
airflow volume adjustment knob / switch between hot and cold air
2.
airflow volume indicator
3. memory buttons (saving entered parameters)
4. SMD rework gun cable
5. SMD rework gun switch on / off
6. soldering iron switch on /off
7. soldering iron smoke absorber switch on / off
8. smoke absorber pipe
9. soldering iron connection socket
10. SMD rework gun working indicator
11. SMD rework gun temperature decreasing button
12. SMD rework gun temperature increasing button
13. SMD rework working mode (AUTO / MANUAL)
14. soldering iron temperature increasing button
15. soldering iron temperature decreasing button
16. soldering iron sleep time indicator
17. SMD rework gun temperature unit (Fahrenheit or Celsius)
18. soldering iron temperature unit (Fahrenheit or Celsius)
19. soldering iron working indicator
20. soldering iron temperature display
21. SMD rework gun temperature display
BEFORE FIRST USE
Upon receipt of the goods, check the packaging for integrity and open it. If the pak-
kaging is damaged, please contact your transport company and distributor within 3
days, and document the damages as detailed as possible. Do not turn the package
upside down! When transporting the package, please ensure that it is kept horizontal
and stable. Please keep all packaging materials (cardboard, plastic tapes and styrofo-
am), so that in case of a problem, the device can be sent back to the service centre in
accurate condition.
Disposing of packaging
The various items used for packaging (cardboard, plastic straps, polyurethane foam)
should be conserved, so that the device can be sent back to the service center in best
conditions in case of problem!
INSTALLING THE APPLIANCE
Appliance location
The work surface where the device will be located must be suitable for the size of
the appliance, please refer to the measurements. The work surface must be levelled,
dry, heat-resistant and at a fitting height from the ground to enable a proper use of
the device.
The power cord connected to the appliance must be properly grounded and corre-
spond to the technical details.
OPERATION – SOLDERING STATION ONLY
1. Device must be placed on stable work table, soldering iron must be placed into
the holder.
2. Fix the appropriate soldering tip and connect the device to the power source.
3. Turn on the device with the main switch placed at the back of the device, turn on
the soldering iron with switch (6), it will start to heat.
4. Temperature setting: set the desired temperature using buttons (14) and (15).
Working (heating) indicator (19) will glow. When the soldering iron reaches the
set temperature, indicator will flash quickly. When the temperature drops, the
indicator turns off.
5. Soldering iron sleep time setting, „SLEEP” is blinking: simultaneously press but-
tons (14) and (15) for about 3 seconds, then using these buttons set the desired
sleep time (16). When the soldering iron is on, and not used (placed in the hol-
der), then after a set time, soldering iron will enter into sleep mode – display will
show “SLP”. If the iron will be picked up from the holder, the device will exit from
the sleep mode and enter into working mode – iron will warms up to a previous-
ly set temperature.
6. Soldering fumes absorption: soldering iron is equipped with soldering fumes
absorption pipe. Absorption can be turned on with switch (7), smoke suction
power can be controlled by the knob (1). It is recommended to carry out regular
inspection and replacement of the smoke absorber filter, which is located on the
front panel under the smoke absorber tube nut (8). The absorber is designed for
solder fume extraction only and may not be uses for other purposes.
7. The device can optionally be equipped with vacuum suction pen (with air hose
and suction tips) designed for displacement of the SMD elements when solde-
ring. In order to use this vacuum suction pen, air hose must be connected to the
smoke absorber socket (8). Suction power can be adjusted by knob (1).
8. After work, the soldering iron should be placed into the holder. Turn off the sol-
dering station by switch (6).
9. If the device is not used for a long time, it should be completely disconnected
from the power source.
OPERATION – SMD REWORK STATION ONLY
1. Device must be placed on stable work table, SMD rework gun must be placed
into the holder.
2. Fix the appropriate nozzle and connect the device to the power source.
3. Turn on the device with the main switch placed at the back of the device, turn on
the SMD rework gun with switch (5), gun is ready to work.
4. Temperature setting: set the desired temperature using buttons (11) and (12).
Working (heating) indicator (10) will glow. When the SMD rework gun reaches
the set temperature, indicator will flash quickly. When the temperature drops, the
indicator turns off.
5.
Airflow volume adjustment: set the desired airflow volume with knob (1). The
volume will be visible on the indicator (2).