background image

AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as 
tool may explode, possibly causing injury.

FITTINGS:

Install a male plug on the tool which is free flowing and which will release air pressure from the tool when 
disconnected from the supply source.

HOSES:

Air hoses should have a minimum of 150 p.s.i. (10.6 kg/cm

2

) working pressure rating or 150 percent of the 

maximum pressure that could be produced in the air system.  The supply hose should contain a fitting that will 
provide “quick disconnecting” from the male plug on the tool.

SUPPLY SOURCE:

Use only clean regulated compressed air as a power source for this tool.  NEVER USE OXYGEN, COMBUSTIBLE
GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE.

REGULATOR:

A pressure regulator with an operating pressure of 0 - 125 p.s.i. is required to control the operating pressure for 
safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. as tool 
may fracture or burst, possibly causing injury.

OPERATING PRESSURE:

Do not exceed recommended maximum operating pressure as tool wear will be greatly increased.  The air supply 
must be capable of maintaining the operating pressure at the tool.  Pressure drops in the air supply can reduce the
tool’s driving power.  Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool.

FILTER:

Dirt and water in the air supply are major causes of wear in pneumatic tools.  A filter will help to get the best 
performance and minimum wear from the tool.  The filter must have adequate flow capacity for the specific 
installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool.  Consult 
the manufacturer’s instructions on proper maintenance of your filter.  A dirty and clogged filter will cause a pressure
drop which will reduce the tool’s performance.

LUBRICATION

Frequent, but not excessive, lubrication is required for best performance.  Oil added through the air line connection 
will lubricate the internal parts.  Use STAN-TECH Air Tool Lubricant, Mobil Velocite #10, or equivalent.  Do 

not 

use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the 
tool, resulting in poor tool performance and frequent tool maintenance.

If no airline lubricator is used, add oil during use into the air fitting on the tool once or twice a day.  Only a few 
drops of oil at a time is necessary.  Too much oil will only collect inside the tool and will be noticeable in the 
exhaust cycle.

COLD WEATHER OPERATION:

For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool 
operation.  We recommend the use of  STAN-TECH WINTER FORMULA air tool lubricant or permanent antifreeze 
(ethylene glycol) as a cold weather lubricant.

CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the tools 

operating valves and mechanisms that could cause tool failure.

NOTE: Some commercial air line drying liquids are harmful to “O”-rings and seals – do not use these low 

temperature air dryers without checking compatability.

-5-

Summary of Contents for SDN11PTB

Page 1: ...E MANUAL BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE IF YOU HAVE ANY QUESTIONS CONTACT YOUR STAN TECH REPRESENTATIVE OR DISTRIBUTOR ...

Page 2: ...ers Air Consumption Regulators Operating Pressure Setting Correct Pressure 8 Lubrication 8 Maintaining the Pneumatic Tool 9 Tool Specifications 9 Loading the Tool 10 Fastener Depth Control 10 Directional Exhaust 10 Driver Length Adjustment 11 Stan Tech warrants to the original retail purchaser that this product is free from defects in material and workmanship and agrees to repair or replace at Sta...

Page 3: ...h air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 When tool is not in use 5 When moving ...

Page 4: ...trip mechanism while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated...

Page 5: ...atic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions on proper maintenance of your filter A dirty and clogged filter will cause a pressure drop which will r...

Page 6: ...ION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when loading operating or servicing this tool Eye protection is required to guard against flying fasteners and debris which could cause severe eye injury The employer and or user must ensure that proper eye protect...

Page 7: ...ontact trip until the nose touches the work surface and then pull the trigger to drive a fastener Do not press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fas tener Remove your finger from the trigger after each operation B RAPID FASTENER OPERATION To operate the tool in this manner hold the tool with the contact trip ...

Page 8: ...gger The trigger must return to the trigger stop on the frame C Pull the trigger and press the contact trip against the work surface THE TOOL MUST NOT CYCLE D With finger off the trigger press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION Use the STAN TECH pneumatic ...

Page 9: ...d hoses or from the effects of dirt and water in the system Restricted air flow will prevent the tool from receiving an adequate volume of air even though the pressure reading is high The results will be slow operation misfeeds or reduced driving power Before evaluating tool problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittin...

Page 10: ...lace quick disconnect fittings Worn piston O ring Replace O ring check driver Tool dry lacks lubrication Use STAN TECH Air Tool Lubricant Damaged pusher spring Replace spring Low air pressure Check air supply system to tool Loose magazine nose screws Tighten all screws Fasteners too short for tool Use only recommended fasteners Bent fasteners Discontinue using these fasteners Wrong size fasteners ...

Page 11: ...ications However in difficult driving applications driver wear of approximately 1 16 1 5mm may cause a slight reduction in the apparent driving power DRIVER LENGTH AND ADJUSTMENT NOTE For Flush Driving length settings shorter than 5 808 147 5mm may be used However the adjusted length should never be less than 5 625 142 8mm or more than 5 828 148mm otherwise normal nailer function may be adversly a...

Reviews: