background image

TOOL OPERATION CHECK:

CAUTION: Remove all fasteners from tool before performing tool operation check.

1.TRIGGER OPERATED TOOL:

A. With finger off the trigger, hold the tool with a firm grip on the handle.

B. Place the nose of the tool against the work surface.

C. Pull the trigger to drive.  Release the trigger and cycle is complete.

CAUTION: THE TOOL WILL CYCLE EACH TIME THE TRIGGER IS PULLED!

2.CONTACT TRIP OPERATION:

A. With finger off the trigger, press the contact trip against the work surface.

THE TOOL MUST NOT CYCLE.

B. Hold the tool off the work surface, and pull the trigger.

THE TOOL MUST NOT CYCLE.

C. With the tool off the work surface, pull the trigger.  Press the contact trip against the work surface.

THE TOOL MUST CYCLE.

D. Without touching the trigger, press the contact trip against the work surface, then pull the trigger.

THE TOOL MUST CYCLE.

3.SEQUENTIAL TRIP OPERATION:

A. Press the contact trip against the work surface, without touching the trigger.

THE TOOL MUST NOT CYCLE.

B. Hold the tool off the work surface and pull the trigger.

THE TOOL MUST NOT CYCLE.
Release the trigger.  The trigger must return to the trigger stop on the frame.

C. Pull the trigger and press the contact trip against the work surface.

THE TOOL MUST NOT CYCLE.

D. With finger off the trigger, press the contact trip against the work surface.  Pull the trigger.

THE TOOL MUST CYCLE.

IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE
THE FOLLOWING FOR SAFE OPERATION

• Use the STAN-TECH pneumatic tool only for the purpose for which it was designed.

• Never use this tool in a manner that could cause a fastener to be directed toward the user or others in the 

work area.

• Do not use the tool as a hammer.

• Always carry the tool by the handle.  Never carry the tool by the air hose.

• Do not alter or modify this tool from the original design or function without approval from 

STAN-TECH.

• Always be aware that misuse and improper handling of this tool can cause injury to yourself and others.

• Never clamp or tape the trigger or contact trip in an actuated position.

• Never leave a tool unattended with the air hose attached.

• Do not operate this tool if it does not contain a legible WARNING LABEL.

NOTE: Do not continue to use a tool that leaks air or does not function properly.  Notify your nearest Stan-Tech 
representative if your tool continues to experience functional problems.

-8-

Summary of Contents for SDN11PTB

Page 1: ...E MANUAL BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE IF YOU HAVE ANY QUESTIONS CONTACT YOUR STAN TECH REPRESENTATIVE OR DISTRIBUTOR ...

Page 2: ...ers Air Consumption Regulators Operating Pressure Setting Correct Pressure 8 Lubrication 8 Maintaining the Pneumatic Tool 9 Tool Specifications 9 Loading the Tool 10 Fastener Depth Control 10 Directional Exhaust 10 Driver Length Adjustment 11 Stan Tech warrants to the original retail purchaser that this product is free from defects in material and workmanship and agrees to repair or replace at Sta...

Page 3: ...h air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 When tool is not in use 5 When moving ...

Page 4: ...trip mechanism while keeping the trigger pulled thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated...

Page 5: ...atic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions on proper maintenance of your filter A dirty and clogged filter will cause a pressure drop which will r...

Page 6: ...ION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when loading operating or servicing this tool Eye protection is required to guard against flying fasteners and debris which could cause severe eye injury The employer and or user must ensure that proper eye protect...

Page 7: ...ontact trip until the nose touches the work surface and then pull the trigger to drive a fastener Do not press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fas tener Remove your finger from the trigger after each operation B RAPID FASTENER OPERATION To operate the tool in this manner hold the tool with the contact trip ...

Page 8: ...gger The trigger must return to the trigger stop on the frame C Pull the trigger and press the contact trip against the work surface THE TOOL MUST NOT CYCLE D With finger off the trigger press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION Use the STAN TECH pneumatic ...

Page 9: ...d hoses or from the effects of dirt and water in the system Restricted air flow will prevent the tool from receiving an adequate volume of air even though the pressure reading is high The results will be slow operation misfeeds or reduced driving power Before evaluating tool problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittin...

Page 10: ...lace quick disconnect fittings Worn piston O ring Replace O ring check driver Tool dry lacks lubrication Use STAN TECH Air Tool Lubricant Damaged pusher spring Replace spring Low air pressure Check air supply system to tool Loose magazine nose screws Tighten all screws Fasteners too short for tool Use only recommended fasteners Bent fasteners Discontinue using these fasteners Wrong size fasteners ...

Page 11: ...ications However in difficult driving applications driver wear of approximately 1 16 1 5mm may cause a slight reduction in the apparent driving power DRIVER LENGTH AND ADJUSTMENT NOTE For Flush Driving length settings shorter than 5 808 147 5mm may be used However the adjusted length should never be less than 5 625 142 8mm or more than 5 828 148mm otherwise normal nailer function may be adversly a...