Ticket Transfer Factor
(The Factory Default Setting for Ticket Transfer Factor is 2).
To make a change to this setting, follow the step by step procedure outlined below. The available range
is 1-9.
Note: The five-position switch and red selection button are located on the dispenser control board for
the ticket dispenser.
1.
Activate the programming mode by setting:
Switch 1–ON; Switch 2-OFF; Switch 3-ON; Switch 4-ON; Switch 5-OFF
2.
Advance to the Ticket Transfer Factor by setting;
Switch 1-ON; Switch 2-OFF; Switch 3-OFF; Switch 4-OFF; Switch 5-OFF
3.
Press the red selection button eight times. This advances you to the correct step (step 9).
4.
Now set switches to desired setting from the Choice numbers 1 through 9 below.
5.
Press the red selection button one time.
6.
End the programming sequence by resetting the switches to the OFF (down) position, and then
press the red selection button one time to put the machine back into service.
TRANSFER FACTOR SETTINGS
CHOICE
SETTING
SWITCH POSITIONS
SW2
SW3
SW4
SW5
1
1
DOWN
DOWN
DOWN
UP
2
2
DOWN
DOWN
UP
DOWN
3
3
DOWN
DOWN
UP
UP
4
4
DOWN
UP
DOWN
DOWN
5
5
DOWN
UP
DOWN
UP
6
6
DOWN
UP
UP
DOWN
7
7
DOWN
UP
UP
UP
8
8
UP
DOWN
DOWN
DOWN
9
9
UP
DOWN
DOWN
UP