CPN700i and CPN1010i Multimedia Chart Plotters
Page 105
1. Press the
key, tap on
Setup Menu
.
2. Turn the
rotary knob or tap on the right bottom arrow to scroll the Desktop Icons to
select
VIDEO
and tap on it. The Video Input menu appears.
3. Tap on
RESTORE DEFAULTS
.
2.13.10 ALARMS
1. Press the
key, tap on
Alarms
. At the bottom of the page the available selections
appear:
SETUP
,
ENGINE
,
GROUNDING
and
SYSTEM
.
Alarms Setup Menu
This menu is used to select and set up audible and visual alarms. See the following table:
Arrival Alarm
:
Alerts when the vessel is approaching a single Destination point or a Waypoint in a Route.
Available selections: 0.00 to 4.99Nm. The default setting is Off.
XTE Alarm
:
Alerts when the vessel is deviating from a defined course. Available selections: 0.00 to
4.99Nm. The default setting is Off.
Depth Alarm
:
Alerts when the received depth value from the optional FF525 50/200kHz BLACK BOX FISH
FINDER is lower than the selected value. Available selections: 0000 to 3278ft. The default
setting is Off.
Anchor Alarm
:
Alerts when the vessel’s position changes more than the selected distance. Available
selections: 0.00 to 4.99Nm. The default setting is Off.
Audible Alarm
:
Enables or disables the alarm beep. The default setting is On.
External Alarm
:
Enables or disables the External Alarm. When any alarm condition occurs the red wire is
switched from High Impedance to Ground. When purchasing the optional buzzer, choose
a 12VDC type with a Max current 400mA or less. The default setting is Off.
Grounding Alarm
:
Looks ahead of the vessel’s heading to see if a potential danger exists. When the Grounding
Alarm is enabled the CPN Series Chart Plotter will draw a triangle in front of the vessel on
the Chart page showing the area that is being searched (see below). The safe depth can be
set using this function. The default setting is Off.
Grounding Alarm Range
: Sets the length of the sector to be detected: 0.25Nm, 0.5Nm and 1.0Nm. The default setting
is Off.
The Grounding Alarm function checks the objects that belong to the standard charts. It does not check
the objects belonging to the VAD categories.
The Grounding Alarm function is available only if a C-MAP 4D SD CARD is inserted. It also affects the
screen redraw speed so we suggest to disable it when not used.
When any of the objects checked are found for the first time, the CPN Series Chart Plotter shows a pop
up window to alert the user of the possible danger. The name of each new dangerous object found is
reported in the Warning window. In the Grounding Alarm Report page the relative item has a check mark
next to it, to identify the dangerous object currently detected. If in the next search cycle the same objects
are found again, the alarm window will not be shown. Instead, if in the next searches the objects found
before are no longer detected, their relevant item in the Grounding Alarm Report page is cleared (note
that in this case, if the same object type is found again later, the Alarm will be shown). The CPN Series
Chart Plotter shows an icon on the charts that identifies when a Grounding Alarm is detected.
Summary of Contents for CPN1010i
Page 1: ......
Page 144: ...CPN700i and CPN1010i Multimedia Chart Plotters Page 145 ...
Page 156: ...CPN700i and CPN1010i Multimedia Chart Plotters Page 157 ...
Page 159: ...Page 160 Owner s Manual ...
Page 163: ...Page 164 Owner s Manual 7 1 7 OPTIONAL FF525 BLACK BOX FISH FINDER ...
Page 188: ......